Paper
7 December 2013 Optimization of physical parameters of 'injected' metal electrodes for capacitively coupled contactless conductivity detection on poly(dimethylsiloxane) microchips
Leigh D. Thredgold, Dmitriy A. Khodakov, Amanda V. Ellis, Claire E. Lenehan
Author Affiliations +
Proceedings Volume 8923, Micro/Nano Materials, Devices, and Systems; 89234D (2013) https://doi.org/10.1117/12.2033616
Event: SPIE Micro+Nano Materials, Devices, and Applications, 2013, Melbourne, Victoria, Australia
Abstract
Capacitively coupled contactless conductivity detection (C4D) and its integration with Lab-on-a-Chip (LOC) systems has been well studied. However, most reported methods require multi-step electrode patterning/fabrication processes which in turn leads to difficulty in consistently aligning detection electrodes. These limitations have the potential to compromise analytical performance of the electrodes and increase the time and cost of device production. We have previously demonstrated a simplified approach for C4D electrode integration with poly(dimethylsiloxane) electrophoresis LOC devices by utilizing ‘injected’ gallium electrodes.1 The developed fabrication process is fast, highly reproducible, and eliminates difficulties with electrode alignment. Using this approach C4D can be readily achieved in any microchip by simply adding extra ‘electrode’ channels to the microchip design. This design flexibility allows for straightforward optimization of electrode parameters. Here, we present the optimization of physical electrode parameters including orientation, length and distance from separation channel. The suitability of the optimized system for on-chip C4D detection was demonstrated through the excellent intra- and inter-day repeatability (< 4 %RSD) of electrophoretically separated lithium, sodium and potassium ions.
© (2013) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Leigh D. Thredgold, Dmitriy A. Khodakov, Amanda V. Ellis, and Claire E. Lenehan "Optimization of physical parameters of 'injected' metal electrodes for capacitively coupled contactless conductivity detection on poly(dimethylsiloxane) microchips", Proc. SPIE 8923, Micro/Nano Materials, Devices, and Systems, 89234D (7 December 2013); https://doi.org/10.1117/12.2033616
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Electrodes

Capacitance

Gallium

Metals

Microfluidics

Lab on a chip

Potassium

Back to Top