Paper
5 June 2003 X-ray tube in parallel magnetic fields
Author Affiliations +
Abstract
Our hybrid x-ray/MR system (a fixed-anode x-ray fluoroscopic system in an interventional MR system) provides the high spatial and temporal resolution of x-ray fluoroscopy with the soft-tissue contrast, 3D visualization and physiological information of MRI. X-rays are produced in an x-ray tube by bombarding a target with high-energy electrons, ionized from the cathode, then accelerated by the electric field between the cathode and anode. In the hybrid system, the x-ray tube is placed in a high magnetic field, aligned to be parallel to the cathode-anode axis of the tube. A finite-element program was used to simulate the electron trajectories in a geometry similar to our fixed anode tube. External magnetic fields parallel to the cathode-anode axis, ranging from 0 to 0.5T, were simulated. Experimentally, focal spot images were acquired using a 30μm pinhole at a magnification of 8.9 in magnetic fields ranging from 0 to 0.5T. No lateral deflection of the focal spot was observed in either the simulation or the experiment, if the magnetic field and the cathode-anode axis were aligned, regardless of the field strength. However, the field strength affected the size and the current density distribution of the focal spot. We conclude that fixed anode x-ray tubes can be used in a magnetic field although its desired electron optics must be fairly “straight” and the cathode-anode axis must be well aligned with the field. Further issues arising from the focal spot size change, such as overheating of the target, and to a lesser extent the system spatial resolution, should be carefully considered.
© (2003) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Zhifei Wen, Rebecca Fahrig, and Norbert J. Pelc "X-ray tube in parallel magnetic fields", Proc. SPIE 5030, Medical Imaging 2003: Physics of Medical Imaging, (5 June 2003); https://doi.org/10.1117/12.480256
Lens.org Logo
CITATIONS
Cited by 9 scholarly publications and 1 patent.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Electrons

Magnetism

X-rays

Magnetic resonance imaging

X-ray detectors

Fluoroscopy

X-ray imaging

RELATED CONTENT

Laser induced x-ray ‘RADAR’ particle physics model
Proceedings of SPIE (May 03 2016)
Seventh-generation CT
Proceedings of SPIE (March 31 2016)
Novel x-ray tube with a line filament
Proceedings of SPIE (November 14 2001)
Development of an MR compatible rotating anode x-ray tube
Proceedings of SPIE (March 18 2008)

Back to Top