5 August 2003 Lamb wave generation with piezoelectric wafer active sensors for structural health monitoring
Author Affiliations +
Abstract
The capability of embedded piezoelectric wafer active sensors (PWAS) to perform in-situ nondestructive evaluation (NDE) is explored. Theoretical developments and laboratory tests are used to prove that PWAS transducers can satisfactorily perform Lamb wave transmission and reception, pulse-echo, pitch-catch, and phased array functions of conventional ultrasonics thus opening the road for embedded ultrasonics. Subsequently, crack detection in an aircraft panel with the pulse-echo method is illustrated. For large area scanning, a PWAS phased array is used to create the embedded ultrasonics structural radar (EUSR). For quality assurance, PWAS self-tests with the electromechanical impedance method are discussed.
© (2003) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Victor Giurgiutiu "Lamb wave generation with piezoelectric wafer active sensors for structural health monitoring", Proc. SPIE 5056, Smart Structures and Materials 2003: Smart Structures and Integrated Systems, (5 August 2003); https://doi.org/10.1117/12.483492
Lens.org Logo
CITATIONS
Cited by 199 scholarly publications and 1 patent.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Ultrasonics

Sensors

Active sensors

Transducers

Wave plates

Structural health monitoring

Nondestructive evaluation