Skip to main content
  • Research article
  • Open access
  • Published:

Is the routine pressure dressing after thyroidectomy necessary? A prospective randomized controlled study

Abstract

Background

An acute complication of thyroidectomy is fatal hematoma, which can produce an upper airway obstruction needing immediate intubation or tracheostomy. After neck surgery, we usually apply a pressure dressing with a non-woven, adhesive fabric to reduce bleeding and fluid collection at the operative bed. We conducted a prospective, randomized, controlled study to evaluate a pressure vs. a non-pressure dressing after thyroid surgery by monitoring blood and serum in the operative bed.

Methods

We studied 108 patients who underwent 116 thyroid surgeries at Srinagarind Hospital, Khon Kaen University, between December 2006 and September 2007. The patients were randomized to either the pressure dressing or non-pressure dressing group. Ultrasound of the neck was performed 24 ± 3 hours after surgery. The volume of fluid collection in the operative bed was calculated. All patients were observed for any post-operative respiratory distress, wound complications, tingling sensation or tetany.

Results

The distributions of age, sex, surgical indications and approaches were similar between the two groups. There was no statistically significant difference in the volume of fluid collection in the operative bed (p = 0.150) and the collected drained content (p = 0.798). The average time a drain was retained was 3 days. One patient in the pressure dressing group suffered cutaneous bruising while one patient in the non-pressure dressing group developed immediate hemorrhage after the skin sutures.

Conclusion

Pressure dressing after thyroidectomy does not have any significant impact on decreasing fluid collection at the operative bed. The use of pressure dressing after thyroidectomy may not therefore be justified.

Trial Registration

NCT00400465, ISRCTN52660978

Peer Review reports

Background

About 200 cases of thyroidectomy are performed per year at Srinagarind Hospital, Khon Kaen University. An acute complication of this operation can lead to a fatal hematoma due to an upper airway obstruction (in 1 to 2.5 percent of cases) [14], requiring either intubation or tracheostomy.

After surgery, we usually apply a pressure dressing using a non-woven, adhesive, fabric to help reduce bleeding and collection of fluid on the basis that it may help to decrease dead space, compress bleeding vessels, decrease the slipping of ligature, the re-opening of cauterized veins, and the oozing area, all of which might precipitate a hematoma at the operative bed. The obvious external evidence of hematoma is a change in the neck contour or bulging skin flaps [5, 6]. These signs may be obscured by a widely closed area of the pressure dressing and may delay detection of the hematoma, leading to airway obstruction.

We conducted a prospective, randomized, controlled study to assess the role of a pressure vs. non-pressure dressing after thyroid surgery, by monitoring fluid accumulation in the operative bed by ultrasound and by collecting serum in suction drains.

Methods

Approval was sought from the Khon Kaen University Ethics Committee for Human Research before initiating the study and informed consent was given by the patients. The study was carried out on 108 patients who underwent 116 thyroid surgeries at Srinagarind Hospital, Khon Kaen University, between December 2006 and September 2007. The discrepancy between the number of patients and the number of surgeries was due to 8 patients having undergone completion thyroidectomies for well-differentiated thyroid carcinomas confirmed by histopathology. These 8 patients were randomized as fresh cases with no consideration given to any previous surgery.

We excluded patients (1) with cervical lymph node metastases requiring neck dissection, (2) clinical or laboratory indicators of coagulation disorders or (3) whose bleeding cannot be stopped by ligation and/or cautery or (4) with anaplastic (undifferentiated) carcinoma, which is typically large and invades adjacent structures.

We stratified patients into two groups according to operation field extension. The first group comprised patients who underwent lobectomy or completion thyroidectomy and the second group patients who underwent subtotal or total thyroidectomy. The patients in each group were then randomized to either the pressure or non-pressure dressing group using a computer-generated randomization list with balanced blocks of unequal size. The treatment assignments were contained in sealed, opaque, sequentially-numbered, individual envelopes. After randomization, a nurse, not involved in the surgery, opened the envelope and independently prepared the dressing material. We used conventional knot-tying ligation for medium-sized vessels and the monopolar electrothermal vessel-sealing system for small-sized vessels to achieve vascular control. The operating surgeon was informed of the assignment group after having completed closure of the wound to avoid bias during operation. In the pressure dressing group, gauze was placed throughout the operative area and pressure applied with a non-woven, adhesive fabric (Hypafix®); in the non-pressure dressing group, gauze was placed on the incision site and held in place with permeable plastic tape (Transpore®).

The closed suction drain, with negative pressure (Radivac®), was threaded through a separate wound. A single drain was used in patients who underwent lobectomy or completion thyroidectomy vs. two closed suction drains for patients who underwent subtotal or total thyroidectomy.

Volume ultrasound (GE Logiq® 9) of the neck was performed after surgery 24 ± 3 hours by the same head and neck radiologist or under his/her supervision. The dressing material was removed at the ward before the patient was taken for ultrasound so as not to apprise the radiologist of the type of dressing. The volume of fluid collection in the operative bed was calculated by measuring the maximum diameter in three dimensions; on the assumption that collection would be in the form of an ellipse or sphere [7]. The volume of fluid collected (in the suction drain) was measured separately. Drains were removed when the fluid collection fell below 10 mL/day. All patients were observed for any post-operative respiratory distress, wound complication, tingling sensation or tetany. The specimens were subjected to histopathological examination for final confirmation of diagnosis. Patients were discharged after drain removal.

The sample-size was calculated based on preliminary data obtained in one month. The 5 patients who underwent thyroidectomy were sent to ultrasound. The mean of fluid volume in surgical bed was 1.53 mL and the standard deviation was 2.5 mL. A sample size of 116 patients was calculated to be able to detect a difference volume of 1.6 mL with a two-sided test with a type 1 error of 5% with a power of 90% and adjusted 5% for dropouts.

Statistical analyses were conducted using Stata (version 9, StataCorp LP, Texas, USA). The normal distributions of data were tested by Kolmogorov-Smirnov test. The effectiveness between the pressure and non-pressure dressing groups were analyzed using the unpaired t test or Mann-Whitney U test for continuous variables vs. the Pearson's χ2-test for categorical variables as appropriate. For all tests, p < 0.05 was considered statistically significant.

Results

Of the 116 thyroid surgeries conducted, there were 15 (12.9%) males and 101 (87.1%) females. The average age of patients was 45.45 years (range, 15–76). Pressure dressings were used for 57 patients and non-pressure dressings for 59. A protocol violation occurred in 2 patients assigned to the pressure dressing group as the surgeon used only one drain instead of two after a subtotal thyroidectomy.

Of the operations performed 65.5% (in 76 patients) were lobectomy. Age and sex were statistically similar between the two groups. The reasons for surgery included: thyroid nodule in 65 (56%) patients, multinodular goiter in 23 (19.8%), Graves' disease in 9 (7.8%) and thyroid carcinoma in 19 (16.4%). The distributions of the surgical indications and approaches were similar between the two groups (Table 1).

Table 1 Demographics, diagnoses and types of thyroid surgery performed

On day one post-surgery, the amount of fluid collection in the operative bed was assessed for both groups using ultrasound. The average volume in the pressure vs. non-pressure dressing groups was 0.195 and 0.408 mL, respectively. The t-test was used to assess for any significant difference in the average amount of fluid collected between the two groups and there was no statistically significant difference in the volume of fluid collected in the operative bed (p = 0.150). The average drained content from the pressure vs. the non-pressure dressing groups was 59.88 and 62.63 mL, respectively, which was not a statistically significant difference (p = 0.798) (Table 2).

Table 2 Volume of fluid in the operative bed and the volume of drained fluid

The average time a drain was retained was 3 days and the average hospital stay was 5 days. There was no statistically significant difference between groups (p = 0.225 and 0.543, respectively). One patient in the pressure dressing group suffered cutaneous bruising; while an immediate hemorrhage after skin suture developed in one patient from the non-pressure dressing group. In the latter case, we re-explored and found ligation material was dislodged from anterior jugular vein. No patient had any post-operative respiratory distress, tingling sensation or tetany (Table 3).

Table 3 Duration of retained drains, complications and length of hospital stay

Discussion

Hematoma is a rare complication of thyroid surgery but the condition can cause an upper airway obstruction, albeit rare (range, 1 to 2.5 percent). The etiology includes slipping of ligature on major vessels (which occurred in this study), reopening of cauterized veins, retching, vomiting, bucking during recovery, valsalva maneuver, increased blood pressure during recovery, large dead space and oozing from the cut area of the thyroid [6]. In our institute, the surgeon usually applies a pressure dressing on the basis that it may help to decrease dead space, compress bleeding vessel and limit the oozing area. Furthermore, it prevents the patient from moving the neck freely which may help to decrease slippage of the ligature or reopening of cauterized veins.

Although many surgeons have gone beyond abandoning a pressure dressing to completely avoiding the use of a drain [8, 9], to our knowledge there has been no prospective randomized study to prove the benefits of pressure dressing in post-thyroidectomy patients. We designed our study to use ultrasonography of the neck to measure fluid collection in the thyroid bed to provide an objective assessment of a method commonly used in many reports [10, 11]. The weakness of our study was that we did not have an objective control of pressure on the skin after applying the pressure or non-pressure dressing. This problem was discussed among the investigators before initiating the study, and we decided not to use the pressure meter because we wanted to make the study approximate regular practice.

Our average hospital stay was slightly longer (5 days) than that of other institutions (3–6 days)[12, 13], perhaps due to the variable definition of hospitalization and the criteria for discharging patients in each study. We admitted patients 1 day prior to surgery and we counted the day we discharged the patient (usually in the morning) as one day. In uncomplicated cases, the patients were discharged from the hospital after drain removal.

In our study, when using a pressure dressing over against a non-pressure dressing, fluid collection at the operative bed and collected drained content was lower in the pressure dressing group. This matched our hypothesis but there was no significant difference. Considering theory on the late detection of hematoma in pressure dressing due to a widely closed area, we did not find either immediate or late hematoma in this group. We suggest that the pressure dressing may have a benefit for preventing hematoma but a larger, randomized, controlled trial is required to establish this practice.

Conclusion

Pressure dressing after thyroidectomy does not provide any significant benefit vis-à-vis decreasing fluid collection at the operative bed. The use of a pressure dressing after thyroidectomy may, therefore, not be justified.

References

  1. Abbas G, Dubner S, Heller KS: Re-operation for bleeding after thyroidectomy and parathyroidectomy. Head Neck. 2001, 23 (7): 544-546. 10.1002/hed.1076.

    Article  CAS  PubMed  Google Scholar 

  2. Agarwal A, Mishra SK: Post-thyroidectomy haemorrhage: an analysis of critical factors in successful management. J Indian Med Assoc. 1997, 95 (7): 418-419, 433.

    CAS  PubMed  Google Scholar 

  3. Blaivas M, Hom DB, Younger JG: Thyroid gland hematoma after blunt cervical trauma. Am J Emerg Med. 1999, 17 (4): 348-350. 10.1016/S0735-6757(99)90083-9.

    Article  CAS  PubMed  Google Scholar 

  4. Palestini N, Tulletti V, Cestino L, Durando R, Freddi M, Sisti G, Robecchi A: [Post-thyroidectomy cervical hematoma]. Minerva Chir. 2005, 60 (1): 37-46.

    CAS  PubMed  Google Scholar 

  5. Harding J, Sebag F, Sierra M, Palazzo FF, Henry JF: Thyroid surgery: postoperative hematoma – prevention and treatment. Langenbecks Arch Surg. 2006, 391 (3): 169-173. 10.1007/s00423-006-0028-6.

    Article  PubMed  Google Scholar 

  6. Savargaonkar A: Post-Thyroidectomy Haematoma Causing Total Airway Obstruction – A Case Report. Indian J Anaesth. 2004, 48 (6): 483-485.

    Google Scholar 

  7. Lee SJ, Ahn IM: Effectiveness of percutaneous ethanol injection therapy in benign nodular and cystic thyroid diseases: long-term follow-up experience. Endocr J. 2005, 52 (4): 455-462. 10.1507/endocrj.52.455.

    Article  CAS  PubMed  Google Scholar 

  8. Corsten M, Johnson S, Alherabi A: Is suction drainage an effective means of preventing hematoma in thyroid surgery? A meta-analysis. J Otolaryngol. 2005, 34 (6): 415-417. 10.2310/7070.2005.34609.

    Article  PubMed  Google Scholar 

  9. Pothier DD: The use of drains following thyroid and parathyroid surgery: a meta-analysis. J Laryngol Otol. 2005, 119 (9): 669-671. 10.1258/0022215054798023.

    Article  PubMed  Google Scholar 

  10. Khanna J, Mohil RS, Chintamani , Bhatnagar D, Mittal MK, Sahoo M, Mehrotra M: Is the routine drainage after surgery for thyroid necessary? A prospective randomized clinical study [ISRCTN63623153]. BMC Surg. 2005, 5: 11-10.1186/1471-2482-5-11.

    Article  PubMed  PubMed Central  Google Scholar 

  11. Schwarz W, Willy C, Ndjee C: [Gravity or suction drainage in thyroid surgery? Control of efficacy with ultrasound determination of residual hematoma]. Langenbecks Arch Chir. 1996, 381 (6): 337-342. 10.1007/BF00191314.

    Article  CAS  PubMed  Google Scholar 

  12. Ahluwalia S, Hannan SA, Mehrzad H, Crofton M, Tolley NS: A randomised controlled trial of routine suction drainage after elective thyroid and parathyroid surgery with ultrasound evaluation of fluid collection. Clin Otolaryngol. 2007, 32 (1): 28-31. 10.1111/j.1365-2273.2007.01382.x.

    Article  CAS  PubMed  Google Scholar 

  13. Terris DJ, Moister B, Seybt MW, Gourin CG, Chin E: Outpatient thyroid surgery is safe and desirable. Otolaryngol Head Neck Surg. 2007, 136 (4): 556-559. 10.1016/j.otohns.2006.09.024.

    Article  PubMed  Google Scholar 

Pre-publication history

Download references

Acknowledgements

The authors thank the staff and nurses at Srinagarind Hospital for their excellent care of the subjects enrolled in this study, Masayoshi Kobayashi, MD. for his advice and Mr. Bryan Roderick Hamman for assistance with the English-language presentation of the manuscript.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Sanguansak Thanaviratananich.

Additional information

Competing interests

The author(s) declare that they have no competing interests.

Authors' contributions

PP designed and supervised the research; collected, analyzed, and interpreted the data; and drafted and revised the manuscript. PV contributed to the conceptual design of the study. WR contributed to the conceptual design and coordinated the project. WP did the ultrasonographic assessments. ST made substantial contributions to the design of the study and approved the final version of the manuscript. All authors read and approved the final manuscript.

Rights and permissions

Open Access This article is published under license to BioMed Central Ltd. This is an Open Access article is distributed under the terms of the Creative Commons Attribution License ( https://creativecommons.org/licenses/by/2.0 ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Reprints and permissions

About this article

Cite this article

Piromchai, P., Vatanasapt, P., Reechaipichitkul, W. et al. Is the routine pressure dressing after thyroidectomy necessary? A prospective randomized controlled study. BMC Ear Nose Throat Disord 8, 1 (2008). https://doi.org/10.1186/1472-6815-8-1

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/1472-6815-8-1

Keywords