The purpose of this research was to investigate the effect of the shape of sodium salicylate (SS) particles on the physical properties as well as the in vitro aerosol performance of the granules granulated by the pressure swing granulation method. SS was pulverized with a jet mill (JM) to prepare the distorted particles, and SS aqueous solution was spray dried (SD) to prepare the nearly spherical particles. The particle size distribution, crushing strength, and pore size distribution of the granules were measured. The adhesive force of the primary particles in the granules was calculated according to Rumpf's equation. The in vitro aerosol performance of the granules was evaluated using a cascade impactor. Both JM and SD particles can be spherically granulated by the pressure swing granulation method without the use of a binder. The size of SD granules was smaller than that of JM granules. Although the crushing strength of the JM and SD granules is almost the same, the internal structures of JM granules and SD granules were found to differ, and the SD particles appear to have been condensed uniformly, resulting in a nearly spherical shape. In the inhalation investigation, the percentage of SS particles of appropriate size delivered to the region for treatment was noticeably higher for SD granules than for JM granules. This finding might be because the adhesive force of the SD primary particles was smaller than that of the JM primary particles in the granules and because the SD granules could be easily separated by air current to obtain the primary particles.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Timsina MP, Martin GP, Marriott C, Ganderton D, Yianneskis M. Drug delivery to the respiratory tract using dry powder inhaler.Int J Pharm. 1994;101:1–13.

    Article  CAS  Google Scholar 

  2. Geldart D. Types of gas fluidization.Powder Technol. 1973;7:285–292.

    Article  CAS  Google Scholar 

  3. Newman SP, Hollingworth A, Clark AR. Effect of different modes of inhalation on drug delivery from a dry powder inhaler.Int J Pharm. 1994;102:127–132.

    Article  CAS  Google Scholar 

  4. Clark AR. Medical aerosol inhalers: past, present, and future.Aerosol Sci Technol. 1995;22:374–391.

    Article  CAS  Google Scholar 

  5. Steckel H, Muler B. In vitro evaluation of dry powder inhalers: influence of carrier particle size and concentration on in vitro deposition.Int J Pharm. 1997;154:31–37.

    Article  CAS  Google Scholar 

  6. Hinto T, Serigano T, Yamamoto H, Takeuchi H, Niwa T, Kawashima Y. Particle design of Wogon extract dry powder inhalation aerosols with gramulation method.Int J Pharm. 1998;168:59–68.

    Article  Google Scholar 

  7. Kawashima Y, Serigano T, Hino T, Yamamoto H, Takeuchi H. Effect of surface morphology of carrier lactose on dry powder inhalation property of pranlukast hydrate.Int J Pharm. 1998;172:179–188.

    Article  CAS  Google Scholar 

  8. Keller M. Innovations and perspectives of metered dose inhalers in pulmonary drug delivery.Int J Pharm. 1999;186:81–90.

    Article  CAS  Google Scholar 

  9. Karhu M, Kuikka J, Kauppinen T, Bergstrom K, Vidgren M. Pulmonary deposition of lactose carriers used in inhalation powders.Int J Pharm. 2000;196:95–103.

    Article  CAS  Google Scholar 

  10. Staniforth JN, Rees JE. Electrostatic charge interactions in ordered powder mixes.J Pharm Pharmacol. 1982;34:69–76.

    CAS  Google Scholar 

  11. Davies PJ, Hanlon GW, Molyneux AJ. An investigation into the deposition of inhalation aerosol particles as a function of air flow rate in a modified “Kirk lung”.J Pharm Pharmacol. 1976;28:908–911.

    CAS  Google Scholar 

  12. Vidgren M, Karkkainen A, Karjalainen P, Paronen P, Nuutinen J. Effect of powder inhaler design on drug deposition in the respiratory tract.Int J Pharm. 1988;42:211–216.

    Article  CAS  Google Scholar 

  13. Nishii K, Ito Y, Kawashima N, Horio M. Pressure swing granulation, a novel binderless granulation by cyclic fluidization and gas flow compaction.Powder Technol. 1996;74:1–6.

    Article  Google Scholar 

  14. Mikami T, Kamiya H, Horio M. Numerical simulation of cohesive powder behavior in fluidized bed.Chem Eng Sci. 1988;53:1927–1940.

    Article  Google Scholar 

  15. Yuasa H, Higashi S, Ozeki T. Preparation of granules for dry powder inhaler by pressure swing granulation method and drug particle delivery.J Pharm Sci Technol Jpn. 2002;62:67–79.

    CAS  Google Scholar 

  16. Yuasa H, Higashi S, Ozeki T. Granulation for dry powder inhaler granules having low hardness by pressure swing granulation method and drug particle delivery in using several kinds of inhalation devices.J Japan Soc Pharm Machinery Eng. 2002;11:6–12.

    Google Scholar 

  17. Watanabe M, Ozeki T, Torii Y, Shibata T, Murakoshi H, Takashima Y, Yuasa H, Okada H. Preparation of two-drug composite granules for dry powder inhalation by pressure swing granulation method and evaluation of their in vitro aerosol performance to lung.J Pharm Sci Technol Jpn. 2003;63:148–157.

    CAS  Google Scholar 

  18. The Handbook of the Japanese Pharmacopoeia. 14th ed. Tokyo, Japan: Hirokawa Publishing Co; 2001:C1383–C1386.

  19. The Handbook of the Japanese Pharmacopoeia. 14th ed. Tokyo, Japan: Hirokawa Publishing Co; 2001:B569–B576.

  20. Rumpf H. Zur theorie der zugfestigkeit von agglomeraten bei kraftubertragung an kontaktpunkten.Chem Ing Tech. 1970;42:538–540.

    Article  Google Scholar 

  21. Ikegami K, Kawashima Y, Takeuchi H, Yamamoto H, Mimura K, Momose D, Ouchi K. A new spherically agglomerated drug composite system with lactose for dry powder inhalation.Adv Powder Technol. 2003;14:215–229.

    Article  CAS  Google Scholar 

  22. Ikegami K, Kawashima Y, Takeuchi H, Yamamoto H, Mimura K, Momose D, Ouchi K. A new agglomerated KSR-592 b-form crystal system for dry powder inhalation formulation to improve inhalation performance in vitro and in vivo.J Control Release. 2003;88:23–33.

    Article  CAS  Google Scholar 

  23. Hino T, Serigano T, Yamamoto H, Takeuchi H, Niwa T, Kawashima Y. Assessment of inertial separation techniques used for pressurized metered dose inhalers to evaluate respiratory deposition of aerosolized Wogon extract dry powder in vitro.STP Pharmacia Sciences. 1997;7:307–314.

    CAS  Google Scholar 

  24. Pitcairn GR, Lankinen T, Seppala OP, Newman SP. Pulmonary drug delivery from the Taifun dry powder inhaler is relatively independent of the patient's inspiratory effort.J Aerosol Med. 2000;13:97–104.

    Article  CAS  Google Scholar 

  25. Newman SP, Pitcairn GR, Adkin DA, Vidgren MT, Silvasti M. Comparison of beclomethasone dipropionate delivery by easyhaler dry powder inhaler and pMDI plus large volume spacer.J Aerosol Med. 2001;14(2):217–225.

    Article  CAS  Google Scholar 

  26. Hirst PH, Bacon RE, Pitcairn GR, Silvasti M, Newman SP. A comparison of the lung deposition of budesonide from Easyhaler, Turbuhaler and pMDI plus spacer in asthmatic patients.Respir Med. 2001;95:720–727.

    Article  CAS  Google Scholar 

  27. Harjunen P, Lehto VP, Martimo K, Suihko E, Lankinen T, Paronen P, Jarbvinen K. Lactose modification enhance its drug performance in the novel multiple dose Taifun DPI.Eur J Pharm Sci. 2002;16:313–321.

    Article  CAS  Google Scholar 

  28. Kinnarinen T, Jarho P, Jarvinen K, Jarvinen T. Pulmonary deposition of a budesonide/gamma-cyclodextrin complex in vitro.J Control Release. 2003;90:197–205.

    Article  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Tetsuya Ozeki.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Watanabe, M., Ozeki, T., Shibata, T. et al. Effect of shape of sodium salicylate particles on physical property and in vitro aerosol performance of granules prepared by pressure swing granulation method. AAPS PharmSciTech 4, 64 (2003). https://doi.org/10.1208/pt040464

Download citation

  • Received:

  • Accepted:

  • DOI: https://doi.org/10.1208/pt040464

Keywords

Navigation