Skip to main content
Advertisement
Browse Subject Areas
?

Click through the PLOS taxonomy to find articles in your field.

For more information about PLOS Subject Areas, click here.

  • Loading metrics

Effect of Axial Eye Length on Retinal Vessel Parameters in 6 to 12-Year-Old Malay Girls

  • Evelyn Li Min Tai ,

    daileid@yahoo.com (ELMT); shatriah@usm.my (IS)

    Affiliations Department of Ophthalmology, School of Medical Sciences, Health Campus, Universiti Sains Malaysia, Kubang Kerian, Kelantan, Malaysia, Hospital Universiti Sains Malaysia, Kubang Kerian, Kelantan, Malaysia

  • Ling-Jun Li,

    Affiliations Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Duke-NUS Medical School, Singapore

  • Wan Hitam Wan-Hazabbah,

    Affiliations Department of Ophthalmology, School of Medical Sciences, Health Campus, Universiti Sains Malaysia, Kubang Kerian, Kelantan, Malaysia, Hospital Universiti Sains Malaysia, Kubang Kerian, Kelantan, Malaysia

  • Tien-Yin Wong,

    Affiliations Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Duke-NUS Medical School, Singapore, Centre for Eye Research Australia, University of Melbourne, Melbourne, Australia

  • Ismail Shatriah

    daileid@yahoo.com (ELMT); shatriah@usm.my (IS)

    Affiliations Department of Ophthalmology, School of Medical Sciences, Health Campus, Universiti Sains Malaysia, Kubang Kerian, Kelantan, Malaysia, Hospital Universiti Sains Malaysia, Kubang Kerian, Kelantan, Malaysia

Abstract

Purpose

Retinal vessel analysis is affected by both systemic and ocular factors. Malays are the major ethnicity in South East Asia. Data on the retinal microvasculature in Malays is limited, especially among children. We aim to evaluate the influence of ocular biometry on retinal vessel parameters in young Malay girls.

Methods

This was a cross-sectional, hospital-based study involving 86 Malay girls aged 6 to 12 years old in Hospital Universiti Sains Malaysia from 2015–2016. Ocular examination, refraction, biometry, retinal photography, and anthropometric measurements were performed. The central retinal arteriolar equivalent (CRAE), central retinal venular equivalent (CRVE) and overall fractal dimension (Df) were measured using validated computer-based methods (Singapore I vessel analyzer, SIVA version 3.0, Singapore). The associations of ocular biometry and CRAE, CRVE and Df were analyzed using multivariable analysis.

Results

The mean CRAE, CRVE and Df in Malay girls were 171.40 (14.40) um, 248.02 (16.95) um and 1.42 (0.05) respectively. Each 1 mm increase in axial length was associated with a reduction of 4.25 um in the CRAE (p = 0.03) and a reduction of 0.02 in the Df (p = 0.02), after adjustment for age, blood pressure and body mass index. No association was observed between axial length and CRVE. Anterior chamber depth and corneal curvature had no association with CRAE, CRVE or Df.

Conclusion

Axial length affects retinal vessel measurements. Narrower retinal arterioles and reduced retinal fractal dimension were observed in Malay girls with longer axial lengths.

Introduction

The human microvasculature, which previously could be evaluated only by relatively invasive methods, is now gradually becoming an open book to us via the retinal circulation [1, 2]. Direct visualization of the retinal vasculature has been simplified by the advent of digital fundus photography, which is rapidly evolving as an integral part of the diagnosis and monitoring of a range of conditions [3]. In adults, retinal vascular calibers and retinal fractal dimensions have been associated not only with ocular problems like diabetic retinopathy [46], but also with various systemic diseases, including hypertension [7, 8], coronary heart disease [9, 10] and stroke [11, 12]. Studies in children are comparatively few, and the available data on these parameters in children has focused mainly on Caucasian and East Asian subjects in Sydney [13], with the contribution from our region being mainly Singaporean Chinese children [14, 15].

A significant proportion of the population living in South East Asia fall under the category of ‘Malay’, or ‘Austronesian people’ [16]. This indigenous group of people has been estimated to number approximately 300 million in South East Asia [17]. However, to the best of our knowledge, apart from a multi-ethnic study by Cheung et al in 2007, no other studies of retinal vessel calibers or fractals in children have included this large ethnic group [14, 18]. In children, the general absence of confounding factors related to systemic and ocular disease makes them an ideal study population not only for acquiring normative data, but also in analyzing the relationship between anatomico-physiological factors and retinal vessel parameters [14]. As retinal vessel analysis has been reported to be affected by a variety of factors, which may differ in different populations, we aim to evaluate the influence of ocular biometry on retinal vessel caliber and retinal fractal dimension in young Malay girls.

Materials and Methods

Study Population

This was a hospital-based, cross-sectional prospective study involving 86 Malay girls aged 6 to 12 years old, conducted in the Ophthalmology Clinic of Hospital Universiti Sains Malaysia between January 2015 and March 2016. The study was approved by the Human Research Ethics Committee USM (USM/JEPeM/1403119) and the conduct of the study followed the tenets of the declaration of Helsinki.

Subjects who fulfilled the inclusion and exclusion criteria were invited to participate. They were included into the study if they were aged between 6 and 12 years old at the time of examination, had best corrected visual acuity better than 6/12, had normal anterior and posterior segment findings and were Malay (both parents and grandparents were Malay). Exclusion criteria was strabismus, amblyopia, optic nerve abnormalities, high refractive errors (based on spherical equivalent of ±4.0 diopters), history of ocular trauma, ocular pathology, systemic illnesses or developmental delay.

Screening was performed by measuring distance visual acuity monocularly using a Snellen chart for distance (Reichert, NY, USA) at six meters. A comprehensive eye examination included a cover test, assessment of extraocular motility, pupillary examination, anterior segment examination and complete retinal evaluation to rule out any ocular conditions which would have precluded participation in the study. Informed written consent for participation in the study was obtained from at least one parent, and verbal assent from the subject.

Refraction and Measurement of Ocular Biometric Parameters

Refraction was performed using an autokeratorefractometer (model RK5; Canon, Inc). Three consecutive readings of sphere and cylinder were obtained; a difference between the lowest and highest readings of up to 0.25 diopters was considered acceptable. Spherical equivalent was taken as the value of the sphere plus half of the value of the cylinder. A non-contact partial coherence interferometer (IOL Master, Carl Zeiss Meditec, Inc, Germany) was used to measure the axial length of the right eye. The mean axial length was derived from an average of five consecutive readings, with a signal-to-noise ratio of more than 2 mm, and a difference of up to 0.05 mm between the lowest and highest reading was considered acceptable. Corneal curvature and anterior chamber depth were likewise derived from a mean of five consecutive readings.

Retinal Photography and Measurement of Retinal Vascular Caliber

After dilation with topical phenylephrine 2.5% and tropicamide 1%, 45 degree digital retinal photographs were taken of the optic disc and macula bilaterally using a digital fundus camera (Model VX-10/KOWA/Japan). Retinal images were then analyzed by a single grader, masked to participant identity and characteristics, using the Singapore I Vessel Algorithm (SIVA) 4.0 cloud software. Right eye fundus photographs were analyzed. In cases where these were ungradable, the images from the left eye were used.

SIVA is a semi-automated computed software, in which all retinal vessels greater than 25 um in diameter located between one-half to two disc diameters from the optic disc margin are outlined, their edges marked using a pixel density histogram, and the retinal arteriolar or venular calibers calculated using the Knudtson-Parr-Hubbard formula [1921]. This formula summarizes the diameters of the six largest arterioles and venules to generate a central retinal arteriolar equivalent (CRAE) and central retinal venular equivalent (CRVE) respectively.

The Bengtsson formula was used to correct for the effect of ocular magnification on retinal vascular caliber measurement [22, 23]. Fractal dimension was calculated by the software from the previously outlined retinal vessels using the ‘box-counting method’, in which the digital retinal image was compartmentalized into equally-sized squares (i.e. boxes), and the number of squares through which the skeletonized (i.e outlined) segments of retinal vessels pass was counted, after which the process was repeated using a differently-sized square [24, 25]. The fractal dimension was the gradient of the logarithm of the number of squares through which the vessel outline passes against the logarithm of the size of the square [7]. Larger values indicated a more complex branching pattern [26].

Anthropometric Measurements

Height and weight were measured with the patient standing barefoot, according to a standard protocol of height and weight measuring scale (Seca model 220; Seca, Hamburg, Germany). Height was recorded to the nearest 1 mm while weight was recorded to the nearest 0.1 kg. Body mass index (BMI) was calculated as weight divided by the height squared (kg per meter squared).

Using an appropriate-sized cuff (bladder length approximately 80% and width 40% of the arm circumference), blood pressure and heart rate was measured in the sitting position after 5 minutes of rest, using a digital automated sphygmomanometer. Two separate readings were taken, after which the average systolic and diastolic blood pressure was calculated. A third attempt would be added if the difference between the first two readings were greater than 10 mm Hg in systolic blood pressure (SBP) and/or 5 mm Hg in diastolic blood pressure (DBP). The formula used to obtain mean arterial pressure (MAP) was one-third of the systolic blood pressure plus two-thirds of the diastolic blood pressure. A data collection sheet was used to document all relevant parameters.

Statistical Analysis

Sample size calculation was performed using G*power 3.1.9.2, with α set at 0.05, power at 0.80 and effect size at 0.15. Statistical analysis was performed using IBM SPSS Statistics for Windows, Version 22.0 (Armonk, NY: IBM Corp). Simple and multiple linear regression were performed to determine the effect of axial length, corneal curvature and anterior chamber depth on retinal vascular calibers and retinal fractal dimension. Two multivariate models were built; Model 1 was adjusted for age, and Model 2 adjusted for age, blood pressure and body mass index. Potential modifiers were examined in stratified analysis. All probabilities quoted are two-sided, and a significant P value was defined as <0.05.

Results

A total of 86 children were included in this study. The mean age was 9.44 ± 1.75 years. Other clinical characteristics; SBP, DBP, MAP and BMI are summarized in Table 1.

The mean spherical equivalent was -0.47 ± 0.72 (diopter). After correcting for ocular magnification, the mean CRAE and CRVE were 171.40 ± 14.40 um and 248.02 ± 16.95 um respectively. The mean retinal fractal dimension was 1.42 ± 0.05. Other ocular parameters are listed in Table 2.

Table 3 shows that in models adjusted for age, BMI and MAP, each 1 mm increase in axial length was associated with a reduction of 4.25 um in the CRAE (p = 0.03) and a reduction of 0.016 in the Df (p = 0.024). No association was found between axial length and CRVE. Anterior chamber depth and corneal curvature were not associated with CRAE, CRVE or Df.

thumbnail
Table 3. Multiple linear regression in association between ocular biometric parameters, retinal vascular caliber and retinal fractal dimension.

https://doi.org/10.1371/journal.pone.0170014.t003

Discussion

Although Malays, whom the anthropologist Blumenbach described as “tawny-coloured, with black hair”, comprise the main ethnic group in South East Asia, the data on retinal vessel parameters in Malays, especially children, is limited [27, 28]. We present new data of the association of ocular biometry with retinal vascular caliber and retinal fractal dimensions in school-going girls of Malay ethnicity. Table 4 summarizes the literature on this association, including our findings.

thumbnail
Table 4. Studies of the association of ocular biometry with retinal vascular caliber.

https://doi.org/10.1371/journal.pone.0170014.t004

We observed that axial length was significantly associated with CRAE. This is consistent with the results of Gopinath et al [29], who evaluated children with no significant refractive error, and Li et al [30], who corrected for ocular magnification. On the contrary, Cheung et al found that after adjusting for ocular magnification, the association between longer axial length and narrower retinal vessels disappeared [31]. As refractive errors are known to affect the measured dimensions of retinal vessels on fundus photography due to differences in ocular magnification, it is important to adjust for this difference. It has been postulated that a longer axial length is associated with a thinner ocular wall and stretched, attenuated retinal vessels [32]. The association of increased axial length with narrowed retinal arterioles may explain the reduced efficiency of the circulation in myopic eyes and indirectly, be related to the pathophysiologic changes seen in this condition [3336].

We noted that anterior chamber depth and corneal curvature were not associated with either CRAE or CRVE. Among Chinese pre-schoolers, Li et al found no significant effect of anterior chamber depth on retinal vessel calibers [30]. Among studies evaluating corneal curvature, however, the results are conflicting. Li et al examined 469 Chinese preschool children and observed that a larger corneal curvature was significantly associated with a narrower CRVE, but not CRAE [30]. Conversely, Gopinath et al reported in their study comprising approximately 5000 preschool and school-aged children, of which 60% were Caucasian, that this association was true for CRAE as well as CRVE [29]. As statistical significance is affected not only by effect size, but also sample size, differences in the latter between our study and previous research may account for these conflicting results.

The association of longer axial lengths with reduced retinal fractal dimensions observed in our study has never been published previously. Retinal fractal dimension acts as a proxy to represent the geometric pattern of the retinal microvasculature, and reflects the complexity of the branching pattern. As fractal dimension is a ratio, rather than an absolute measurement, it is not affected by the effect of magnification [37]. Retinal fractal dimensions have previously been shown to be affected by blood pressure [15] and nutrition [38], but not by body mass index [39]. Smaller retinal fractal dimensions have been observed in children with higher blood pressure, leading researchers to hypothesize that this change may reflect rarefaction of the microvasculature [15]. At this point in time, we are unable to explain the significance of the observed association between axial length and retinal fractal dimension. One possible explanation for it is that when the rate of eyeball elongation surpasses that of the retinal vessels, the latter become stretched and attenuated, resulting in a reduced fractal dimension. Alternately, axial length may somehow affect the measurement of this retinal vessel parameter by yet unknown mechanisms. Future research is required to explore the clinical relevance of these new findings, as no prior studies have explored this association.

We found that measurement of retinal vessel parameters in children is a simple, convenient and non-invasive method of assessing the body’s microvasculature. Another strength of our study is its homogenous sample of the main ethnic group in South East Asia, thus eliminating any effect of ethnic variations on retinal vessel measurements. Furthermore, use of a standardized protocol for ocular biometry, a validated software for retinal vessel analysis, and adjustment for potential confounders ensures the reliability of these measurements.

Few limitations of this study must be acknowledged. First, all our study participants were girls. Although Cheung et al found no significant gender differences in retinal vascular caliber among children [14], we acknowledge that repeating this study among boys will provide a better overall clinical picture of the effect of axial length in children. As this is a cross-sectional study, further prospective studies would give a better picture of the temporal changes in retinal vessels. Also, the potential for measurement error due to magnification with regard to retinal vessel calibers cannot be fully eliminated, but only minimized. As the formulas developed to adjust for magnification errors still do not encompass the full scope of camera and optical magnification, quantification of absolute retinal vessel diameters remains challenging. As such, retinal fractal dimension may be a better reflection of vessel parameters than retinal vessel caliber.

Conclusion

Our study shows that axial length significantly affects retinal vessel caliber and fractal dimension in Malay girls. Adjustment for axial length is necessary for future retinal vessel analysis.

Supporting Information

S1 Table. Systemic, ocular and retinal vascular parameters of study subjects.

https://doi.org/10.1371/journal.pone.0170014.s002

(PDF)

Author Contributions

  1. Conceptualization: ELMT IS.
  2. Formal analysis: LJL.
  3. Funding acquisition: ELMT.
  4. Investigation: ELMT IS.
  5. Methodology: ELMT IS.
  6. Resources: ELMT TYW.
  7. Software: TYW.
  8. Supervision: WHWH IS.
  9. Validation: TYW.
  10. Visualization: WHWH IS.
  11. Writing – original draft: ELMT.

References

  1. 1. Wong TY, Klein R, Klein BE, Tielsch JM, Hubbard L, Nieto FJ. Retinal microvascular abnormalities and their relationship with hypertension, cardiovascular disease, and mortality. Surv. Ophthalmol. 2001;46(1):59–80. Epub 2001/08/30. pmid:11525792
  2. 2. Patton N, Aslam T, Macgillivray T, Pattie A, Deary IJ, Dhillon B. Retinal vascular image analysis as a potential screening tool for cerebrovascular disease: a rationale based on homology between cerebral and retinal microvasculatures. J. Anat. 2005;206(4):319–48. Epub 2005/04/09. pmid:15817102
  3. 3. Bernardes R, Serranho P, Lobo C. Digital ocular fundus imaging: a review. Ophthalmologica. 2011;226(4):161–81. pmid:21952522
  4. 4. Dirani M, McAuley AK, Maple-Brown L, Kawasaki R, McIntosh RL, Harper CA, et al. Association of retinal vessel calibre with diabetic retinopathy in an urban Australian indigenous population. Clin. Experiment. Ophthalmol. 2010;38(6):577–82. Epub 2010/05/12. pmid:20456440
  5. 5. Lim SW, Cheung N, Wang JJ, Donaghue KC, Liew G, Islam FM, et al. Retinal vascular fractal dimension and risk of early diabetic retinopathy: A prospective study of children and adolescents with type 1 diabetes. Diabetes care. 2009;32(11):2081–3. Epub 2009/08/20. pmid:19690082
  6. 6. Broe R. Early risk stratification in pediatric type 1 diabetes. Acta ophthalmologica. 2015;93 Thesis 1:1–19. Epub 2015/02/24.
  7. 7. Cheung CY, Thomas GN, Tay W, Ikram MK, Hsu W, Lee ML, et al. Retinal vascular fractal dimension and its relationship with cardiovascular and ocular risk factors. American journal of ophthalmology. 2012;154(4):663–74 e1. Epub 2012/07/31. pmid:22840482
  8. 8. Chew SK, Xie J, Wang JJ. Retinal arteriolar diameter and the prevalence and incidence of hypertension: a systematic review and meta-analysis of their association. Current hypertension reports. 2012;14(2):144–51. Epub 2012/02/11. pmid:22322543
  9. 9. Wong TY, Kamineni A, Klein R, Sharrett AR, Klein BE, Siscovick DS, et al. Quantitative retinal venular caliber and risk of cardiovascular disease in older persons—The Cardiovascular Health Study. Arch. Intern. Med. 2006;166(21):2388–94. pmid:17130394
  10. 10. Liew G, Mitchell P, Rochtchina E, Wong TY, Hsu W, Lee ML, et al. Fractal analysis of retinal microvasculature and coronary heart disease mortality. European heart journal. 2011;32(4):422–9. Epub 2010/12/09. pmid:21138936
  11. 11. Kawasaki R, Xie J, Cheung N, Lamoureux E, Klein R, Klein BE, et al. Retinal microvascular signs and risk of stroke: the Multi-Ethnic Study of Atherosclerosis (MESA). Stroke; a journal of cerebral circulation. 2012;43(12):3245–51. Epub 2012/11/01.
  12. 12. Kawasaki R, Che Azemin MZ, Kumar DK, Tan AG, Liew G, Wong TY, et al. Fractal dimension of the retinal vasculature and risk of stroke: a nested case-control study. Neurology. 2011;76(20):1766–7. Epub 2011/05/18. pmid:21576694
  13. 13. Rochtchina E, Wang JJ, Taylor B, Wong TY, Mitchell P. Ethnic variability in retinal vessel caliber: a potential source of measurement error from ocular pigmentation?—the Sydney Childhood Eye Study. Invest. Ophthalmol. Vis. Sci. 2008;49(4):1362–6. Epub 2008/04/04. pmid:18385051
  14. 14. Cheung N, Islam FM, Saw SM, Shankar A, de Haseth K, Mitchell P, et al. Distribution and associations of retinal vascular caliber with ethnicity, gender, and birth parameters in young children. Invest. Ophthalmol. Vis. Sci. 2007;48(3):1018–24. Epub 2007/02/28. pmid:17325141
  15. 15. Kurniawan ED, Cheung N, Cheung CY, Tay WT, Saw SM, Wong TY. Elevated blood pressure is associated with rarefaction of the retinal vasculature in children. Invest Ophthalmol Vis Sci. 2012;53(1):470–4. Epub 2011/12/30. pmid:22205607
  16. 16. World Atlas International Edition. Chicago:: Rand McNally 1944.
  17. 17. Rosman M, Zheng Y, Wong W, Lamoureux E, Saw SM, Tay WT, et al. Singapore Malay Eye Study: rationale and methodology of 6-year follow-up study (SiMES-2). Clin. Experiment. Ophthalmol. 2012;40(6):557–68. Epub 2012/02/04. pmid:22300454
  18. 18. Cheung N, Saw SM, Islam FM, Rogers SL, Shankar A, de Haseth K, et al. BMI and retinal vascular caliber in children. Obesity (Silver Spring). 2007;15(1):209–15. Epub 2007/01/18.
  19. 19. Knudtson MD, Lee KE, Hubbard LD, Wong TY, Klein R, Klein BE. Revised formulas for summarizing retinal vessel diameters. Curr Eye Res. 2003;27(3):143–9. Epub 2003/10/17. pmid:14562179
  20. 20. Hubbard LD, Brothers RJ, King WN, Clegg LX, Klein R, Cooper LS, et al. Methods for evaluation of retinal microvascular abnormalities associated with hypertension/sclerosis in the Atherosclerosis Risk in Communities Study. Ophthalmology. 1999;106(12):2269–80. Epub 1999/12/22. pmid:10599656
  21. 21. Patton N, Aslam TM, MacGillivray T, Deary IJ, Dhillon B, Eikelboom RH, et al. Retinal image analysis: concepts, applications and potential. Progress in retinal and eye research. 2006;25(1):99–127. Epub 2005/09/13. pmid:16154379
  22. 22. Bengtsson B, Krakau CET. Correction of optic disc measurements on fundus photographs. Graefe's Arch Clin Exp Ophthalmol. 1992;230(1):24–8.
  23. 23. Wong TY, Wang JJ, Rochtchina E, Klein R, Mitchell P. Does refractive error influence the association of blood pressure and retinal vessel diameters? The Blue Mountains Eye Study. American journal of ophthalmology. 2004;137(6):1050–5. Epub 2004/06/09. pmid:15183789
  24. 24. Masters BR. Fractal analysis of the vascular tree in the human retina. Annual review of biomedical engineering. 2004;6:427–52. Epub 2004/07/17. pmid:15255776
  25. 25. Stosic T, Stosic BD. Multifractal analysis of human retinal vessels. IEEE transactions on medical imaging. 2006;25(8):1101–7. Epub 2006/08/10. pmid:16895002
  26. 26. Zhu P, Huang F, Lin F, Li Q, Yuan Y, Gao Z, et al. The relationship of retinal vessel diameters and fractal dimensions with blood pressure and cardiovascular risk factors. PLoS ONE. 2014;9(9):e106551. Epub 2014/09/05. pmid:25188273
  27. 27. Population Distribution and Basic Demographic Characteristic Report 2010. Malaysia: Department of Statistics, 2010 (Updated: 05/08/2011).
  28. 28. Blumenbach JFB, Thomas; Marx, Karl Friedrich Heinrich; Flourens, P. (Pierre); Wagner, Rudolf; Hunter, John. The anthropological treatises of Johann Friedrich Blumenbach. London: Longman, Green, Longman, Roberts, & Green 1865. 480 p.
  29. 29. Gopinath B, Wang JJ, Kifley A, Tan AG, Wong TY, Mitchell P. The association between ocular biometry and retinal vascular caliber is comparable from early childhood to adolescence. Invest Ophthalmol Vis Sci. 2013;54(2):1501–8. Epub 2013/01/19. pmid:23329666
  30. 30. Li LJ, Cheung CY, Gazzard G, Chang L, Mitchell P, Wong TY, et al. Relationship of ocular biometry and retinal vascular caliber in preschoolers. Invest. Ophthalmol. Vis. Sci. 2011;52(13):9561–6. Epub 2011/11/09. pmid:22064996
  31. 31. Cheung N, Tikellis G, Saw SM, Amirul Islam FM, Mitchell P, Wang JJ, et al. Relationship of axial length and retinal vascular caliber in children. Am. J. Ophthalmol. 2007;144(5):658–62. Epub 2007/09/18. pmid:17869206
  32. 32. Nemeth J, Michelson G, Harazny J. Retinal microcirculation correlates with ocular wall thickness, axial eye length, and refraction in glaucoma patients. J. Glaucoma. 2001;10(5):390–5. Epub 2001/11/17. pmid:11711836
  33. 33. Luzhnov PV, Shamaev DM, Iomdina EN, Tarutta EP, Markosyan GA, Shamkina LA, et al. [Transpalpebral Tetrapolar Reoophtalmography in the Assessment of Parameters of the Eye Blood Circulatory System]. Vestn. Ross. Akad. Med. Nauk. 2015(3):372–7. Epub 2015/10/27. pmid:26495728
  34. 34. Akyol N, Kukner AS, Ozdemir T, Esmerligil S. Choroidal and retinal blood flow changes in degenerative myopia. Can. J. Ophthalmol. 1996;31(3):113–9. Epub 1996/04/01. pmid:8743218
  35. 35. Dastiridou AI, Ginis H, Tsilimbaris M, Karyotakis N, Detorakis E, Siganos C, et al. Ocular rigidity, ocular pulse amplitude, and pulsatile ocular blood flow: the effect of axial length. Invest. Ophthalmol. Vis. Sci. 2013;54(3):2087–92. Epub 2013/03/07. pmid:23462745
  36. 36. Shimada N, Ohno-Matsui K, Harino S, Yoshida T, Yasuzumi K, Kojima A, et al. Reduction of retinal blood flow in high myopia. Graefes Arch. Clin. Exp. Ophthalmol. 2004;242(4):284–8. Epub 2004/01/15. pmid:14722781
  37. 37. Liew G, Wang JJ, Cheung N, Yong PZ, Hsu W, Mong LL, et al. The Retinal Vasculature as a Fractal: Methodology, Reliability, and Relationship to Blood Pressure. Ophthalmol 2008; 115:1951–6
  38. 38. Gopinath B, Flood VM, Wang JJ, Smith W, Rochtchina E, Louie JC, et al. Carbohydrate nutrition is associated with changes in the retinal vascular structure and branching pattern in children. The American journal of clinical nutrition. 2012;95(5):1215–22. Epub 2012/03/30. pmid:22456656
  39. 39. Gopinath B, Baur LA, Teber E, Liew G, Wong TY, Mitchell P. Effect of obesity on retinal vascular structure in pre-adolescent children. International journal of pediatric obesity: IJPO: an official journal of the International Association for the Study of Obesity. 2011;6(2–2):e353–9. Epub 2010/10/05.