Vitamin C and aberrant electrolyte results

  • Qing H. Meng , William C. Irwin and Kishore Visvanathan

Abstract

Vitamin C interferes with assays involving the redox-reaction. However, the interference of Vitamin C with electrolytes has not been reported. In the present case, we describe a 61-year-old lady with severe electrolyte abnormalities after administration of high doses of vitamin C. This patient, who had terminal colon cancer, presented to hospital with anuria. Her electrolytes were extremely abnormal (determined on the Beckman Synchron LX20): serum sodium 200mmol/L, potassium 7.0mmol/L, and chloride 50mmol/L. Repeated measurements showed similar abnormalities. However, these critical abnormalities did not fit her clinical picture, as she was alert with normal vital signs. One of the specimens was also run on both the ABL700 and the Bayer644 analyzers, and the electrolytes appeared normal. Pooled serum from healthy individuals to which various amounts of vitamin C was added then was analyzed on Beckman Synchron LX20 for electrolytes, demonstrating the interference of vitamin C consistent with the initial finding. Thus, we eventually figured out that the aberrant results were due to the vitamin C caused analytical interference.


Corresponding author: Dr. Qing H. Meng, Department of Pathology, Room 4917, Royal University Hospital, University of Saskatchewan, 103 Hospital Drive, Saskatoon, SK, S7N 0W8, Canada Phone: +1-306-655-2165, Fax: +1-306-655-2193,

References

1 Pauling L. Evolution and the need for ascorbic acid. Proc Natl Acad Sci USA 1970; 67: 1643–8. 10.1073/pnas.67.4.1643Search in Google Scholar PubMed PubMed Central

2 Englard S, Seifter S. The biochemical functions of ascorbic acid. Annu Rev Nutr 1986; 6: 365–406. 10.1146/annurev.nu.06.070186.002053Search in Google Scholar PubMed

3 Badrick TC, Campbell B. Effects of intravenous infusion of ascorbate on common clinical chemistry tests. Clin Chem 1992; 38: 2160. 10.1093/clinchem/38.10.2160aSearch in Google Scholar

4 Kroll MH, Elin RJ. Interference with clinical laboratory analyses. Clin Chem 1994; 40: 1996–2005. 10.1093/clinchem/40.11.1996Search in Google Scholar

5 White-Stevens RH, Stover LR. Interference by ascorbic acid in test systems involving peroxidase. II. Redox-coupled indicator systems. Clin Chem 1982; 28: 589–95. Search in Google Scholar

6 Spencer K. Analytical reviews in clinical biochemistry: the estimation of creatinine. Ann Clin Biochem 1986; 23: 1–25. 10.1177/000456328602300101Search in Google Scholar PubMed

7 Siest G, Appel W, Blijenberg GB, Capolaghi B, Galteau MM, Heusghem C, et al. Drug interference in clinical chemistry: studies on ascorbic acid. J Clin Chem Clin Biochem 1978; 16: 103–10. 10.1515/cclm.1978.16.2.103Search in Google Scholar PubMed

8 Freemantle J, Freemantle MJ, Badrick T. Ascorbate inter-ferences in common clinical assays performed on three analyzers. Clin Chem 1994; 40: 950–1. 10.1093/clinchem/40.6.950Search in Google Scholar

9 Zoppi F, Fenili D. Drug interferences in reactions for detecting hydrogen peroxide by means of peroxidase. Clin Chem 1980; 26: 1229–30. 10.1093/clinchem/26.8.1229Search in Google Scholar

10 Pesce MA, Bodourian SH. Interference with the enzymic measurement of cholesterol in serum by use of five reagent kits. Clin Chem 1977; 23: 757–60. 10.1093/clinchem/23.4.757Search in Google Scholar

11 Moshides JS. Comparison of ascorbic acid interference in HDL-cholesterol estimation by six precipitation methods, with use of a sensitive enzymic cholesterol reagent. Clin Chem 1987; 33: 1467–8. 10.1093/clinchem/33.8.1467aSearch in Google Scholar

Published Online: 2011-9-21
Published in Print: 2005-4-1

© by Walter de Gruyter Berlin New York

Downloaded on 28.3.2024 from https://www.degruyter.com/document/doi/10.1515/CCLM.2005.080/html
Scroll to top button