1 June 2014 LOW FLOW OXYGEN THERAPY FROM A PORTABLE OXYGEN CONCENTRATOR OR AN OXYGEN CYLINDER EFFECTIVELY TREATS HYPOXEMIA IN ANESTHETIZED WHITE-TAILED DEER (ODOCOILEUS VIRGINIANUS)
Åsa Fahlman, Nigel Caulkett, Murray Woodbury, Tanya Duke-Novakovski, Vincent Wourms
Author Affiliations +
Abstract

For treatment of hypoxemia, delivery of the minimum effective oxygen flow rate is advantageous during field anesthesia because it prolongs the life of the oxygen cylinder. Portable oxygen concentrators as the oxygen source require less logistical considerations than cylinders and are a safer alternative during helicopter field work because they are nonexplosive devices. The objective of this study was to evaluate low oxygen flow rates by continuous or pulsed intranasal delivery for treatment of hypoxemia in anesthetized white-tailed deer (Odocoileus virginianus). Nine captive adult female deer (body mass 56–72 kg) were physically restrained in a drop-floor chute and hand injected intramuscularly with medetomidine (0.1–0.14 mg/kg) and ketamine (2.5–4.3 mg/kg). Intranasal oxygen was delivered from an oxygen cylinder at continuous flow rates of 1 and 2 L/min or from a battery driven oxygen concentrator (EverGoTM Portable Oxygen Concentrator, Respironics®) with pulse-dose delivery (maximum capacity of 1.05 L/min). The pulse-dose setting (pulse volume 12–70 ml) was adjusted according to the respiratory rate. Arterial blood gases were analyzed before, during, and after O2 supplementation. A 10-min washout period was allowed between treatment groups. All three treatments adequately treated hypoxemia. The partial pressure of arterial oxygenation increased significantly from baseline values of 55 ± 10 to 115 ± 31 mm Hg during supplementation from the oxygen concentrator, to 138 ± 21 mm Hg during supplementation from the oxygen cylinder at 1 L/min, and to 201 ± 42 mm Hg at 2 L/min. In conclusion, low flow rates of intranasal oxygen supplemented continuously from an oxygen cylinder or by pulsed delivery from a portable oxygen concentrator effectively treated hypoxemia in anesthetized white-tailed deer.

American Association of Zoo Veterinarians
Åsa Fahlman, Nigel Caulkett, Murray Woodbury, Tanya Duke-Novakovski, and Vincent Wourms "LOW FLOW OXYGEN THERAPY FROM A PORTABLE OXYGEN CONCENTRATOR OR AN OXYGEN CYLINDER EFFECTIVELY TREATS HYPOXEMIA IN ANESTHETIZED WHITE-TAILED DEER (ODOCOILEUS VIRGINIANUS)," Journal of Zoo and Wildlife Medicine 45(2), 272-277, (1 June 2014). https://doi.org/10.1638/2013-0097R.1
Received: 6 May 2013; Published: 1 June 2014
KEYWORDS
Anesthesia
hypoxemia
immobilization
oxygen concentrator
oxygen therapy
wildlife
RIGHTS & PERMISSIONS
Get copyright permission
Back to Top