Abstract
Pencil graphite electrodes modified with Co(II), Ni(II), Cu(II) and Fe(II) metallophthalocyaninetetrasulfonates (MePcTSs) were investigated for an electrochemical determination of bisphenol A (BPA). The electrochemical performances of the modified electrodes for different pH values in phosphate and the Britton–Robinson buffers were determined by cyclic voltammetry; the electrode performances were better in the Britton–Robinson buffer. NiPcTS and CoPcTS modifications of the electrodes had remarkable enhancements on their performances. The differential pulse voltammetry parameters for the electrodes were optimized, and we found that the electrochemical response versus the concentration of BPA is linear from 5.0 × 10–7 to 1.0 × 10–5 M for the NiPcTS and CoPcTS modified electrodes. The detection limits of these modified electrodes are 2.9 × 10–7 and 4.3 × 10–7 M, respectively, and the effects of interfering species are less than 5%. The results show that NiPcTS and CoPcTS modified pencil graphite electrodes could be used for electrochemical determinations of BPA for analytical purposes.
Similar content being viewed by others
References
A. M. Soto and C. Sonnenschein, Nat. Rev. Endocrinol., 2010, 6, 363.
B. S. Rubin, J. Steroid. Biochem., 2011, 727, 27.
G. Mileva, S. L. Baker, A. T. M. Konkle, and C. Bielajew, Int. J. Environ. Res. Public Health, 2014, 77, 7537.
S. D. Richardson, Anal. Chem., 2009, 87, 4645.
A. V. Krishnan, P. Statins, S. F. Permuth, L. Tokes, and D. Feldman, Endocrinology, 1993, 732, 2279.
A. Goodson, W. Summerfield, and I. Cooper, Food Addit. Contam., 2002, 79, 796.
W. Korner, U. Bolz, and W. Sumuth, Chemosphere, 2000, 40, 1131.
A. M. Calafat, J. Weuve, X. Ye, L. T. Jia, H. Hu, S. Ringer, K. Huttner, and R. Hauser, Environ. Health Persp., 2009, 777, 639.
A. Ballesteros-Gómez, S. Rubio, and D. Pérez-Bendito, J. Chromatogr. A, 2009, 7276, 449.
N. C. Maragou, E. N. Lampi, N. S. Thomaidis, and M. A. Koupparis, J. Chromatogr. A, 2006, 7729, 165.
N. K. Wilson, J. C. Chuang, C. Lyu, R. Menton, and M. K. Morgan, J. Exp. Anal. Env. Epid., 2003, 73, 187.
D. Zalko, C. Jacques, H. Duplan, S. Bruel, and E. Perdu, Chemosphere, 2011, 82, 424.
N. Arnich, M. C. Canivenc-Lavier, M. Kolf-Clauw, H. Coffigny, J. P. Cravedi, K. Grob, A. C. Macherey, D. Masset, R. Maximilien, J. F. Narbonne, F. Nesslany, J. Stadler, and J. Tulliez, Int. J. Hyg. Environ. Health, 2011, 274, 271.
H. S. Yin, Y. L. Zhou, and S. Y. Ai, J. Electroanal. Chem., 2009, 626, 80.
J. Sajiki, K. Takahashi, and J. Yonekubo, J. Chromatogr. B, 1999, 736, 255.
H. Sambe, K. Hoshina, K. Hosoya, and J. Haginaka, Analyst, 2005, 730, 38.
R. S. Garcia and P. P. Losada, J. Chromatogr. A, 2004, 7032, 37.
O. Ros, A. Vallejo, L. Blanco-Zubiaguirre, M. Olivares, A. Delgado, N. Etxebarria, and A. Prieto, Talanta, 2015, 734, 247.
K. Ouchi and S. Watanabe, J. Chromatogr. B, 2002, 780, 365.
T. Tsukioka, J. Brock, S. Graiser, J. Nguyen, H. Nakazawa, and T. Makino, Anal. Sci., 2003, 79, 151.
K. V. Ragavan, N. K. Rastogi, and M. S. Thakur, Trends Anal. Chem., 2013, 52, 248.
C. Barrera, I. Zhukov, E. Villagra, F. Bedioui, M. A. Paez, J. Costamagna, and J. H. Zagal, J. Electroanal. Chem., 2006, 589, 212.
L. Özcan, Y. Sahin, and H. Türk, Biosens. Bioelectron., 2008, 24, 512.
I. C. Lopes, D. D. Souza, S. A. S. Machado, and A. A. Tanaka, Anal. Bioanal. Chem., 2007, 388, 1907.
V. Chauke, F. Matemadombo, and T. Nyokong, J. Hazard. Mater., 2010, 778, 180.
V. P. Chauke, E. Antunes, and T. Nyokong, J. Electroanal. Chem., 2011, 667, 1.
K. Hou, L. Huang, Y. Qi, C. Huang, H. Pan, and M. Du, Mater. Sci. Eng., C, 2015, 49, 640.
J. Huang, X. Zhang, Q. Lin, X. He, X. Xing, H. Huai, W. Lian, and H. Zhu, Food Control, 2011, 22, 786.
Q. Wang, Y. Wang, S. Liu, L. Wang, F. Gao, F. Gao, and W. Sun, Thin Solid Films, 2012, 520, 4459.
Y. Zhang, Y. Cheng, Y. Zhou, B. Li, W. Gu, X. Shi, and Y. Xian, Talanta, 2013, 707, 211.
W. Gao, J. Song, and N. Wu, J. Electroanal. Chem., 2005, 576, 1.
J. Huang, X. Zhang, S. Liu, Q. Lin, X. He, X. Xing, and W. Lian, J. Appl. Electrochem., 2011, 47, 1323.
R. Shen, W. Zhang, Y. Yuan, G. He, and H. Chen, J. Appl. Electrochem., 2015, 45, 343.
L. Özcan and Y. Sahin, Sens. Actuators, B, 2007, 727, 362.
L. Özcan, M. Sahin, and Y. Sahin, Sensors, 2008, 8, 5792.
M. Vestergaard, K. Kerman, and E. Tamiya, Anal. Chim. Acta, 2005, 538, 273.
J. Wang, A. N. Kawde, and E. Sahlin, Analyst, 2000, 725, 5.
J. H. Weber and D. H. Busch, Inorg. Chem., 1965, 4, 472.
J. C. Obirai and T. Nyokong, J. Electroanal. Chem., 2007, 600, 251.
A. B. P. Lever, E. R. Milaeva, and G. Speier, “Phthalocyanines: Properties and Applications”, ed. C. C. Leznoff and A. B. P. Lever, 1993, Vol. 3, VCH, New York.
N. Grootboom and T. Nyokong, Anal. Chim. Acta, 2001, 432, 49.
J. H. Zagal, S. Griveau, J. F. Silva, T. Nyokong, and F. Bedioui, Coord. Chem. Rev., 2010, 254, 2755.
S. Maree and T. Nyokong, J. Electroanal. Chem., 2000, 492, 120.
W. Chen W. Lu, Y. Yao, and M. Xu, Environ. Sci. Technol., 2007, 47, 6240.
K. Aoki, Y. Guo, and J. Chen, J. Electroanal. Chem., 2009, 629, 73.
A. J. Bard and L. R. Faulkner, “Electrochemical Methods: Fundamentals and Applications”, 2001, John Wiley and Sons, New York, Chichester, Weinheim, Brisbane, Singapore, Toronto.
Acknowledgments
The authors thank the Scientific Research Project Council of Afyon Kocatepe University (BAP Project Number: 11.FEN. BIL.01) for financial support and Dr. Justin Beck (Pennsylvania State University) for his useful suggestions.
Author information
Authors and Affiliations
Corresponding author
Electronic supplementary material
Rights and permissions
About this article
Cite this article
Özcan, L., Altuntaş, M., Büyüksağiş, A. et al. Electrochemical Determination of Bisphenol A with Pencil Graphite Electrodes Modified with Co(II), Ni(II), Cu(II) and Fe(II) Phthalocyaninetetrasulfonates. ANAL. SCI. 32, 881–886 (2016). https://doi.org/10.2116/analsci.32.881
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.2116/analsci.32.881