One of the key factors determining the performance of a 110–500-kV station service voltage transformer (SSVT) is a compact insulation design that provides minimum winding sizes. Since SSVTs are new equipment that combine the operational features of a power transformer and the design features of a measuring voltage transformer, it is necessary to study the characteristic transient processes occurring under the impact of lightning-impulse test voltages and lightning and switching overloads in operation in order to ensure proper insulation design. The article presents the results of an experimental investigation of impulse transients in the windings of a full-scale mockup model of an active part of a 20-kV A SSVT with a rated voltage of 110 kV. The influence of grounding the low-voltage winding terminals on the maximum values and duration of impulse stresses on the longitudinal insulation of the high-voltage winding is revealed. It is shown that, unlike in the case of power transformers with disc windings, more significant effects on the insulation are produced when no load is applied on the low-voltage windings.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Larin, V.S., Matveev, D.A., and Nikulov, I.I., The use of power transformers from 110–500 kV overhead lines, Energoekspert, 2017, nos. 5–6.

  2. Lokhanin, A.K., Coordination of isolation of power transformers with reduced insulation level, Elektrichestvo, 2010, no.2.

  3. RD 16 312–86. Transformatory silovye. Elektricheskaya prochnost’ izolyatorov vitkov obmotok (RD 16 312–86. Power Transformers. Electric Strength of Insulation of Coil Windings), Moscow: Minist. Elektrotekh. Prom-sti SSSR, 1986.

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to A. V. Zhuikov.

Additional information

Original Russian Text © A.V. Zhuikov, M.A. Kubatkin, D.A. Matveev, S.I. Khrenov, V.S. Larin, I.I. Nikulov, 2018, published in Elektrotekhnika, 2018, No. 5, pp. 22–26.

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Zhuikov, A.V., Kubatkin, M.A., Matveev, D.A. et al. Studying the Impulse Overloads in the Windings of a Station Service Voltage Transformer. Russ. Electr. Engin. 89, 309–312 (2018). https://doi.org/10.3103/S1068371218050139

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.3103/S1068371218050139

Keywords

Navigation