Next Article in Journal
Application of Repetitive Transcranial Magnetic Stimulation in Neuropathic Pain: A Narrative Review
Next Article in Special Issue
Do Patients with Bronchiectasis Have an Increased Risk of Developing Lung Cancer? A Systematic Review
Previous Article in Journal
Dynamics of Epiretinal Membrane Peeling under Perfluorocarbon Liquid Evaluated by Intraoperative OCT
Previous Article in Special Issue
Clinical Stage III NSCLC Patients Treated with Neoadjuvant Therapy and Surgery: The Prognostic Role of Nodal Characteristics
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Review

Endoscopic Technologies for Peripheral Pulmonary Lesions: From Diagnosis to Therapy

1
Department of Pulmonology, University Hospital of Udine (ASUFC), 33100 Udine, Italy
2
Respiratory Medicine Unit, Department of Medicine, University of Verona and Verona University Hospital, 37134 Verona, Italy
*
Author to whom correspondence should be addressed.
Life 2023, 13(2), 254; https://doi.org/10.3390/life13020254
Submission received: 13 December 2022 / Revised: 7 January 2023 / Accepted: 9 January 2023 / Published: 17 January 2023
(This article belongs to the Special Issue Thoracic Malignancies: From Prevention and Diagnosis to Late Stages)

Abstract

:
Peripheral pulmonary lesions (PPLs) are frequent incidental findings in subjects when performing chest radiographs or chest computed tomography (CT) scans. When a PPL is identified, it is necessary to proceed with a risk stratification based on the patient profile and the characteristics found on chest CT. In order to proceed with a diagnostic procedure, the first-line examination is often a bronchoscopy with tissue sampling. Many guidance technologies have recently been developed to facilitate PPLs sampling. Through bronchoscopy, it is currently possible to ascertain the PPL’s benign or malignant nature, delaying the therapy’s second phase with radical, supportive, or palliative intent. In this review, we describe all the new tools available: from the innovation of bronchoscopic instrumentation (e.g., ultrathin bronchoscopy and robotic bronchoscopy) to the advances in navigation technology (e.g., radial-probe endobronchial ultrasound, virtual navigation, electromagnetic navigation, shape-sensing navigation, cone-beam computed tomography). In addition, we summarize all the PPLs ablation techniques currently under experimentation. Interventional pulmonology may be a discipline aiming at adopting increasingly innovative and disruptive technologies.

1. Introduction

1.1. The Definition of PPLs

Peripheral pulmonary lesions (PPLs) are focal radiographic opacities undetectable by flexible bronchoscopy direct inspection [1,2]. Detection and diagnosis of PPLs represent a serious challenge for radiologists, thoracic surgeons, and respiratory physicians. The radiologic detection of PPLs has significantly increased during the last decades owing to the implementation of lung cancer screening programs [3]. Nowadays, PPLs are frequently incidental findings. They are reported in 0.2% of chest radiographs [4,5] and 13% of routinely performed chest computed tomography (CT) scans [6].

1.2. Evaluation and Risk Assessment of PPLs

PPLs may correspond to benign and malignant entities localized at the periphery of the lung. According to the National Lung Screening Trial findings, the early diagnosis of PPLs is associated with a 20% reduction in lung-cancer-specific mortality [7]. Thanks to this and other studies [8,9], guidelines have been proposed that recommend an annual low-dose chest CT scan screening for high-risk individuals (ages 55 to 77 years with ≥30 pack-year history of smoking, who are current smokers or have quit within the past 15 years) [10].
Histological diagnosis is of paramount importance to early detect malignant lesions. The decision whether to proceed to the histological sampling of the PPL depends on the radiographic appearance of the lesion and the presence of various patient’s related risk factors. Hence, when a PPL is identified, it is necessary to proceed with a risk stratification based on the patient profile and the characteristics found on chest CT. Patients with PPL are often asymptomatic, and when symptoms are present, they may reflect the etiologic condition underlying the development of the PPL [11]. Risk factors such as smoking, history of lung diseases, or malignancy need to be considered [12,13,14,15,16,17,18]. It is critical to recognize nodules with a high likelihood of being malignant and require further examination, while avoiding unneeded investigations for nodules with a lesser likelihood of cancer.
Primary lung cancer comprises an extensive range of histological types [19,20]. The primary historical division considered the distinction between small-cell lung cancer (SCLC) and nonsmall-cell lung cancer (NSCLC), the latter of which makes up about 85% of lung histotypes [21].
Among NSCLC, we should further categorize a few histotypes: squamous cell carcinoma (derived from squamous epithelial cells and mostly centrally located) [22,23], adenocarcinoma (which has a tendency to be peripheral and derives from bronchial mucosal tissue or alveolar surface epithelium), and large-cell carcinoma [24]. Among the ones cited, adenocarcinoma is the most common histotype of malignant PPLs [24]. Regarding the prognosis of malignant PPLs, data on this appear to be mixed, and undoubtedly histologic differentiation seems to play a role [22,23,24,25,26,27,28,29,30,31,32,33]. In many studies, no comparison is made between malignant lesion’s peripheral and central locations. As of today, it appears clear that histological subsets of malignant PPLs tend to have a faster growth rate than central ones [25,26,27,34], although there appears to be no difference in the chemotherapy failure rate [27,33,35]. Moreover, centrally located malignant lesions are frequently inoperable or unsuitable for radical surgical treatment, have a worse prognosis than early-stage malignant PPLs, which are possibly treatable with surgical resection (lobectomy, segmentectomy, wedge resection) [26,36].
Patients frequently have an advanced stage of disease at the time of diagnosis due to the delay of symptom presentation, especially for PPLs, which impairs survival [37]. Fortunately, we are currently entering an era of lung cancer screening. The National Lung Screening Trial in the U.S. demonstrated the benefit on mortality with lung cancer screening derived from the use of low-dose high-resolution CT (HRCT) [38]. Subsequently, other studies have shown evidence to support this practice, which allows the detection of pulmonary neoplastic lesions in an early stage, very often represented by PPLs [8,9]. Thanks to these studies, it is currently possible to carry out an early diagnosis and therapy in lung cancer cases [39].

1.3. Initial Approach to PPLs

The first-line examination is either a bronchoscopy with tissue sampling or computed-tomography-guided transthoracic needle aspiration (CT-TTNA) [40]. Traditional bronchoscopic techniques have low diagnostic accuracy for most PPLs, especially the smallest ones. Notably, it has been estimated that the diagnostic yield of bronchoscopy for PPLs ≤2 cm is only 14% vs. 31% for those >2 cm [41]. CT-TTNA offers an alternative procedure for sampling PPLs with a reported diagnostic yield superior to 50% [42,43,44,45]. However, CT-TTNA is associated with a significant incidence of pneumothorax (45%), requiring chest tube placement in up to 15% of patients [46]. In addition, CT-TTNA does not allow mediastinal staging and has a non-negligible rate of false negative results (30%), mostly with small lesions [47,48,49,50]. For this reason, CT-TTNA alone may not rule out a malignant diagnosis [51].
Fluorine 18 fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET-CT) may add relevant information in the staging and risk stratification phase of a PPL, especially for solitary pulmonary nodules. It is considerably more likely that solid lung nodules larger than 8 mm in diameter that do not significantly uptake 18F-FDG are benign [52]. However, despite the usefulness of the examination, this is not a substitute for actual tissue sampling [53].
Notwithstanding, over the last years, several novel tools have improved the traditional endoscopic techniques for the diagnostic sampling and, eventually, staging of PPLs. Ultrathin bronchoscopy, radial-probe endobronchial ultrasound (RP-EBUS), virtual navigation bronchoscopy, electromagnetic navigation (EMN), shape-sensing navigation, augmented fluoroscopy, cone-beam computed tomography (CBCT), and robotic bronchoscopy (RB) are now game changers for the interventional pulmonologist (IP). As will be discussed in this review, these minimally invasive procedures aimed at both diagnosis and therapy of PPLs, have been recently introduced in real-life practice, and their safety and efficacy are still under evaluation. We strongly believe that these techniques will lead to a general improvement in the prognosis and personalization of the patient management path.

2. Methodology of the Review

This narrative review evaluates the existing literature by collecting the primary English language bibliographic references in international scientific databases (Medline, Pubmed, Scopus, and Google Scholar). The search strategy aimed to include the most significant documents dealing with the diagnosis of PPLs by using the following keywords in combination with the Boolean operator OR and: interventional pulmonology, bronchoscopy, lung nodule, peripheral lung lesion, lung cancer, lung cancer screening, endobronchial ultrasound, ultrathin bronchoscopy, lung navigation, robotic bronchoscopy, cone-beam computed tomography, and lung ablation. The interval considered by the research was from January 2009 to November 2022. Other references considered significant were included by the authors.
Systematic reviews with meta-analyses, randomized control trials (RCTs), and research were included in our review. We also reviewed the guidelines for diagnosing pulmonary lesions by the leading scientific societies.
To minimize bias, two authors (M.M., A.F.) independently carried out the search, deduplicated the research results, screened the articles, and selected the studies to be included in this review. Of note, the list of included references is not necessarily all-encompassing but reflects the body of evidence believed appropriate to the purpose of this document: highlighting the latest progress made in the endoscopic diagnosis and therapy for PPLs.

3. Endoscopic Identification of a PPL

When a PPL is identified, the IP decides whether and how to approach it based on the lesion’s morphology outlined on the chest CT scan [26,54]. CT patterns, such as the presence of a bronchus sign and a lesion size of >20 mm, are predictors of adequate sampling [55,56]. In addition, operator experience and high institutional procedural volumes positively impact the diagnostic yield and accuracy of PPLs [57].
During the navigation to the lesion and sampling procedure, the IP will consider all aspects aimed at maximizing the diagnostic yield: adequate sedation of the patient, collection of at least five bioptic samples, and the use of rapid on-site evaluation (ROSE) of the sample on slides set up in the endoscopic room. These considerations maximize the possibility of achieving success in reaching and withdrawing a significant sample from the lesion and minimizing the risk of repetition of the procedure due to insufficient tissue material [58,59,60,61,62].
The latest guidelines from the American College of Chest Physicians encourage using minimally invasive modalities [2]. Nonetheless, there is no clear evidence comparing the yield of these types of endoscopic techniques for diagnosing PPLs. Therefore, the choice between the techniques mainly depends on IP expertise and available technology.
All the technologies available for the IP may improve the performance of PPL sampling procedures (Table 1).

3.1. Ultrathin Bronchoscopy

In the past, flexible bronchoscopy (FB) did not allow direct visualization of the more peripheral airways, as the caliber of the instrumentation available for the adult patient was large. For this reason, since 1985, Prakash hypothesized using small-sized pediatric bronchoscopes to navigate to the periphery and to reach and sample PPLs [63]. However, conventional bronchoscopes tend to be large-sized (outer diameter >4 mm), making reaching the more distal bronchial branches difficult. For this reason, in recent years, ultrathin bronchoscopes have been developed.
Although a universal definition of ultrathin bronchoscopy does not exist, experts generally consider ultrathin bronchoscopes as those with an outer diameter of 2.8–3.5 mm [64,65]. The small size of ultrathin bronchoscopes allows passing through smaller airways to reach more peripherally located PPLs. In addition, dedicated miniaturized sampling instruments (e.g., needles and forceps) may be introduced through the small working channels to sample these lesions.
Even though the ultrathin bronchoscope can reach the most distal airways, it might not allow direct visualization of PPLs. For this reason, its use may be combined with RP-EBUS, fluoroscopy, and navigation systems to address this limitation. The diagnostic yield for the multimodal sampling of PPLs may exceed 70% and is strictly associated with the lesion’s size and the presence of the bronchus sign [66,67,68].

3.2. Endobronchial Ultrasound

Both convex-probe endobronchial ultrasound (CP-EBUS) and RP-EBUS may aid PPLs sampling. CP-EBUS allows direct observation and a contemporary minimally invasive sampling of anatomical structures beyond the airway walls [69]. It can be used in sampling PPLs in contact with the central airways: lesions in the upper lobes, close to the trachea, or the lower lobes, close to the main bronchi [70].
RP-EBUS represents a way to confirm the real-time positioning of the bronchoscope relative to the lesion to be sampled. By locating the area surrounding the PPL, RP-EBUS maximizes the sample quality and reduces the risk of iatrogenic pneumothorax [71,72,73]. Its use is often associated with other guiding technologies such as fluoroscopy [74,75], EMN [76], or CBCT [77]. A guide sheath may also be used to direct the path of the sampling tool between the bronchoscope and the lesion after retracting the RP-EBUS probe [78,79].
Overall, the diagnostic yield of bronchoscopy with RP-EBUS for PPLs has been estimated at around 69–73% [1,80]. As expected, the diagnostic yield strongly depends on the PPL’s size and the probe’s position relative to the PPL [80]. Nonetheless, several authors have consistently demonstrated that the yield for RP-EBUS guided sampling of PPLs is sensibly higher than that of traditional transbronchial biopsies [81].
According to the ACCP guidelines, RP-EBUS should be prioritized for the first sampling of PPLs [82].

3.3. Navigation Systems

FB aimed at sampling PPLs has been historically performed under fluoroscopic guidance [78]. However, new auxiliary navigation systems have progressively been developed to assist the IP in navigating within the bronchi. In fact, advancement and orientation become progressively more complex as the bronchoscope moves further into the periphery [83]. These systems rely on preprocedural CT images to obtain a three-dimensional (3D) airway model and a pathway. The former can be used for real-time navigation guidance within the airway to reach an estimated proximal zone to the PPL [84,85]. The significant advantages of these navigation systems are evident in cases where CT-guided biopsy or the classical fluoroscopy-guided bronchoscopy are not safe due to PPL-related factors (e.g., underlining emphysema, proximity to a major vessel) or in cases where previous sampling has been nondiagnostic, when a long procedure is needed for both lesion sampling and mediastinal staging, when sampling of multiple lesions is necessary, and to obtain large quantities of tissue for molecular analysis [86].
A significant limit of these technologies is the presence of a high discrepancy between the position of the PPL estimated by the navigation technology and its actual anatomical position. The difference between the PPL’s theoretical and actual position has been defined as CT-to-body divergence and represents a phenomenon explained by the dynamic condition of the lung parenchyma during the procedure [87]. The lung exhibits movements associated with ventilation and progressively, during the procedure, with zonal atelectasis [88].

3.3.1. Virtual Bronchoscopy

The navigation technologies that have first been introduced in clinical practice are virtual bronchoscopy and electromagnetic navigation (EMN). Virtual bronchoscopy is a CT-based imaging technique that allows a noninvasive intraluminal evaluation of the tracheobronchial tree. In addition, the airways’ and carina’s mucosa morphology may be evaluated noninvasively, and airway exploration via imaging software may aid in the mental mapping of the route to the PPL [89].
Virtual navigation bronchoscopy (VNB; Archimedes System) uses the patient’s CT scan to represent the airway via pattern recognition software [90]. In other terms, VBN allows navigation to the PPL by simultaneously aligning actual bronchoscopy views and virtual views. Since VNB alone may not definitively confirm the localization of the target PPL, the virtual pathway derived from VNB may be coupled with fluoroscopy (fused fluoroscopic guidance) or RP-EBUS. [91] The primary benefit given by this technology is the 3D reconstruction of the vascular structures, theoretically allowing to reach a PPL by the transparenchymal route (bronchial transparenchymal nodule access), creating a path through the lung parenchyma while avoiding the vascular structures, even in the absence of a bronchus sing [92]. The accuracy of VNB systems strongly relies on the quality of the radiological data [93]. Overall, the diagnostic yield of VNB on PPL has been reported from 67 to 74% [93,94,95].

3.3.2. Electromagnetic Navigation

EMN (superDimension, SPiN Perc System, Monarch) initial trials occurred in 2005 [96]. The technology is based on virtual bronchoscopy planning software and a “location board” emitting low-frequency electromagnetic waves. Results from the chest CT data are combined with the electromagnetic field board to guide the real-time tracking of endoscopic instruments to reach the PPL. Specifically, via an extended working channel, the locatable guiding probe is advanced in the airway with the help of a steerable catheter. The probe orientation is identified in 3D space through the electromagnetic field [97]. Likewise, in VNB, the procedure’s outcome depends mainly on the quality of the baseline CT investigation and the preprocedural mapping of the pathways leading to the target lesion. Current implementations include active correction of the EMN guidance system’s position with a standard C-arm fluoroscope (superDimension; Medtronic, digital tomosynthesis-electromagnetic navigational bronchoscopy) [98]. EMN may also be combined with RP-EBUS [99]. According to the two most extensive meta-analyses focusing on EMN, the overall diagnostic yield of EMN on PPLs ranges from 64 to 67% [100,101]. Sensible variability in diagnostic yields exists, depending on the lesion’s size, location, combination with RP-EBUS, radiological patterns, and sampling instruments [101]. Interestingly, the use of EMN has been proven safe even in the presence of pacemakers and defibrillators [102,103].

3.3.3. Shape-Sensing Navigation

Shape-sensing navigation (ION, Intuitive Surgical) is a novel guidance system sold only in conjunction with the ION robotic bronchoscopy technology, which tracks the position of a dedicated articulating catheter [98]. A thin fiber embedded along the catheter’s entire length provides the basis for the system, measuring its length and shape hundreds of times per second while displaying its shape and position relative to the surrounding anatomy [104]. The guide allows strict closed-loop control to maintain the catheter in the correct position for sampling. The main advantage of this technology is the absence of magnetic fields and the absence of interaction with metal objects (e.g., pacemakers). To date, very few experiences with shape-sensing navigation have been reported. A premarketing study found that the ION system reached PPLs with a mean size of 14 mm in 96.6% of cases, with an overall diagnostic yield of 79.3% [105]. A small prospective analysis conducted in the U.S. demonstrated a diagnostic yield of 86% with shape-sensing navigation for PPLs with a mean diameter of <2 cm [106]. More recently, J. Reisenauer et al. found that the ION system allowed obtaining a sample of adequate quality in 95% of the samplings [107].

3.4. CBCT and Augmented Fluoroscopy

Implementing CBCT in clinical practice represented one of the last decade’s most critical advances in interventional pulmonology. This type of technology uses a rotating C-arm that generates intraprocedural images with a quality almost similar to a chest CT [108,109,110]. CBCT provides 3D reconstructions by combining coronal, sagittal, and axial views, which are invaluable during navigation. This system supports the physicians in confirming the intraprocedural location of the target PPLs [111]. In addition, the accurate real-time confirmation of the “tool-in-lesion sign” allows the confirmation of the instrumentation within the PPL and consequently guides tissue sampling [112]. Another essential feature of CBCT is the ability to detect atelectasis, which may limit the navigation and visualization of the target [111]. Eventually, CBCT can be combined with other techniques, such as ultrathin scopes, RP-EBUS, and EMN. It has been estimated that the diagnostic yields of CBCT combined with traditional bronchoscopy and EMN reach 70% and 87.5%, respectively [112,113].
Multiple companies have developed their version of both portable and fixed CBCT systems [111,114,115,116,117,118]. When considering using CBCT, physicians should remember that this technique causes significant radiation exposure, needs a complex workflow, and lengthens the procedural time [111]. For this reason, adequate training is required for its use, and a close relationship between the PI and the radiologist is indispensable. In managing the device, the specific procedural needs must be carefully balanced with the radiological exposure of the patient and the staff of the endoscopy room [119].
Augmented fluoroscopy (AF) is a novel technology that combines a baseline CT image derived from either a preprocedural chest CT or an intraprocedural scan performed by CBCT with real-time fluoroscopic guidance [120]. This technology is integrated into the processing software of some CBCT devices [121] or can be purchased separately (LungVision, Body Vision Ltd., Ramat Ha Sharon, Israel) [120,122]. This process provides 3D live fluoroscopic guidance. Through AF, the IP can localize the smallest PPLs dynamically and compensate for respiratory motion during navigation and sampling [121].
CBCT combined with AF has shown a significantly high diagnostic yield [123]. Recently, C.K. Lin et al. retrospectively reviewed the diagnostic yield of endoscopic procedures conducted with CBCT and AF (CBCT-AF) and compared them to those conducted without AF. As expected, the CBCT-AF group had a significantly higher diagnostic yield, especially for smaller lesions (68.8% in the CBCT-AF group vs. 0% in the non-AF group, p = 0.026 for lesions ≤ 10 mm, and 77.5% vs. 46.4%, p = 0.016, respectively, for lesions between 10 and 20 mm).

3.5. Robotic Bronchoscopy

Robotic endoscopic systems for bronchoscopy (RB) are experiencing a progressive global diffusion, limited, as for most iconic robotic technologies, by the high cost of acquiring the technology and its consumables [124,125].
Currently, only two platforms are available (Monarch and ION by Intuitive Surgical), with more to come [126]. Both devices’ steerable catheters have a small outer diameter, making it feasible for them to reach the peripheral areas of the lung, theoretically improving stability and control over traditional bronchoscopy and increasing diagnostic yield [126]. However, despite RB reaching deeper into the lung, lesion size still plays a role in diagnostic accuracy. The risk of complications is still high due to inexperience with the technique and the absence of widely shared international protocols on its use and the management of intraprocedural complications (e.g., bleeding) [127,128].

3.6. Others

Other promising technologies are awaiting final scientific support for their widespread implementation in clinical practice.
Confocal laser endomicroscopy (CLE) allows in vivo imaging of tissues. Alveolar spaces may be visualized with a miniprobe (Alveoflex), usually introduced in the lung periphery with a guide sheath [129]. This technique may be used before sampling a PPL to confirm the appropriate position of the probe relative to the lesion and allow in vivo cellular imaging by direct observation or after topical administration of specific dyes [129,130]. CLE-observed features might even identify lung carcinoma directly in ex vivo samples [131,132] and have been proposed as a substitute for ROSE [133].
Optical coherence tomography (OCT) is an imaging technique based on near-infrared light. The dedicated radial probe creates images using near-infrared light scattering with a 15 µm resolution. OCT provides an advantage over endobronchial ultrasonography because light waves can be used in air-filled anatomical compartments without requiring a transducing medium or direct contact with the tissue [134]. The system can directly generate two-dimensional images and carry out three-dimensional reconstructions using the dedicated software. The technology has only recently been introduced in the context of the assessment of PPLs [135]. Patterns visualized by OCT also correlate with PPL’s malignancy [136].

4. Treatment of PPLs with Endoscopic Ablation Techniques

Current guidelines recommend surgical resection for early-stage NSCLC in patients eligible for radical treatment [137]. However, the site of the disease and the patient’s comorbidities may make the patient unsuitable for surgery [138,139]. In fact, unresectable disease, typically represented by stage III and IV disease, may be approached surgically only in the context of salvage surgery or after a course of neoadjuvant therapy [140,141,142]. In addition, lung cancer patients, due to their age and exposure to risk factors such as cigarette smoking, are frequently affected by other diseases such as chronic obstructive pulmonary disease, heart failure, ischemic heart disease, arterial hypertension, atrial fibrillation, cerebrovascular disease, and peripheral vascular disease [143,144]. These pathologies may both exclude eligibility for surgery or worsen postoperative survival outcomes, a matter still neglected in the medical literature [145,146]. The only other option remaining with a radical intent is stereotaxic body radiation therapy, which, despite its effectiveness, bears significant adverse effects [147,148,149,150]. For all these reasons, endoscopic approaches have progressively become more investigated due to the reduced risk of short-term and long-term complications [151].
Potential uses for bronchoscopy include pleural dye marking of PPLs for surgical resection [152,153,154,155], placement of fiducial markers for radiotherapy [149,156,157], and direct ablation [158]. The latter is mainly an active research field, currently distant from clinical practice but rapidly progressing and supported by a large IP community.
Dye marking of a PPL has a practical utility in identifying lesions otherwise not visible or palpable by the surgeon, allowing shorter operating times and possibly carrying out minor resection operations, such as segmentectomies or wedge resections [155,159]. Indeed, the identification of small PPLs and confirmation of their complete resection can be challenging. Factors such as small size, ground-glass appearance on CT, and ample distance from the pleural surface make it difficult to identify a lesion intraoperatively [152,155]. The defect of this procedure lies in the fact that it must be carried out temporally close to the surgical procedure, often in the same operating room, as the dye may not have a long half-life [155]. The dyes currently available are methylene blue [155,160,161,162,163], indigo carmine [159], and indocyanine green [164,165].
Fiducial markers (FMs) for radiotherapy may be positioned with EMN or RP-EBUS guidance [149,156]. Generally, they are composed of a nitinol filament attached to a gold seed. Different types of FM are available: linear, coil-tailed, coil-spring, and two-band [149]. The main adverse event related to this procedure is the migration of the positioned marker [166,167].
Bronchoscopic ablation technologies (Table 2) include radiofrequency ablation (RFA), microwave ablation (MWA), photodynamic therapy (PDT), brachytherapy, cryoablation, laser ablation, bronchial thermal vapor thermal ablation, and direct therapeutic injection [158,168]. Many of these techniques are currently in the early stages of application in humans, and many clinical trials are being developed to study their efficacy in real life.
RFA uses an electromagnetic wave, delivering a thermal injury to the PPL via an electrode inserted directly into the lesion [169]. The therapeutic application of this technology is based on the assumption that cancer cells generally are more susceptible to heat than normal cells [169]. A high-frequency alternating current provokes coagulation of the tissue surrounding the electrode itself [170]. Due to the limited heatable radius, PPLs with a diameter smaller than 30 mm are best suited to this treatment. Given the current limitations of navigation technology for the periphery of the lung and the limited ability to place a catheter within a lesion located eccentrically to the afferent bronchus, RFA remains suitable for lesions with a bronchus sign on chest CT. New BTPNA access could offer a method to access lesions with no bronchus sign, and bronchoscopic RFA may be performed using this technology in the future [92]. Data on RFA of PPLs is still growing, but a recent study showed a local control rate higher than 80% and a 5-year survival rate of 60% after treatment [171].
MWA employs microwave frequency ranges between 300 MHz and 300 GHz to induce coagulative necrosis by heating the tissue at temperatures above 60 °C. The MWA antenna is usually set at a power level between 40 and 80 W, and the duration of exposure time ranges between 5 and 10 min for each PPL depending on its features (shape, size, and pattern). [172] Multiple human clinical trials are ongoing; see the respective National Clinical Trial (NCT) numbers: NCT05281237, NCT05532527, NCT04889989, NCT04369872, NCT04755738, and NCT05053802, with one having already delivered good preliminary results (NCT03603652) [173]. MWA produces a more extensive and uniform ablation zone than RFA because it generates a higher temperature in a shorter amount of time and is less susceptible to high impedance from high temperatures and heat sink effect [174,175]. Additionally, for MWA, direct ablation without saline infusion between the applicator tip and the target is possible for air-rich lesions such as ground-glass opacities (GGOs). As a result, MWA has benefits and excels at treating lung cancer that exhibits a GGO pattern [172,176].
PDT requires the preprocedural intravenous administration of a photosensitizing agent (a haematoporphyrin derivative) preferentially taken up by malignant cells [177]. Next follows the local endobronchial application of polarized light, usually red light at a 630 nm wavelength, which induces the intracellular production of reactive oxygen species, provoking local cell death [178,179]. Due to the difficulty of identifying a patient to whom it is appropriate to apply this technology and who can tolerate the adverse events related to the photosensitizing agent (e.g., sunburn), it remains scarcely widespread [177].
Brachytherapy involves the endoluminal administration of high-dose radiation therapy. This technology was previously applied to central airway malignancies but has been gradually abandoned. Only one study using this technology in the PPL research field has been completed (NCT00107172). Moreover, there are no currently ongoing clinical trials [180].
Cryoablation induces cell death using an alternation of freeze and thaw cycles. Although still not widely used, a Japanese trial has shown good survival following the cryoablation treatment of an inoperable NSCLC [181,182]. Treatment with cryoablation is particularly effective in poorly vascularized malignant lesions [183].
Laser ablation or bronchoscopic laser interstitial thermal therapy (BLITT) is an evolution of the classic treatment of centrally located endobronchial lesions [158,184]. A diode laser is applied by a laser delivery fiber (LDF) with a wide aperture, inducing tissue charring. The LDF may be advanced through the bronchial wall directly into the lung parenchyma. It was first evaluated in animal studies [184], and the first human trial ended recruiting this year (NCT03707925) with pending results.
Bronchial thermal vapor ablation entails the delivery of steam at a high temperature causing colliquative necrosis of the tissues distal to the treated area. Bacterial pneumonia and inflammatory pneumonitis following treatment are frequent [185]. It may be a potential treatment for localized lung cancer; however, the evidence is still unclear, and the first human trials are ongoing (NCT03198468 and NCT03514329).
Direct therapeutic injection aims at the intralesional administration of therapeutic drugs at high concentrations, limiting systemic administration side effects. The first evidence of the application of this technique dates back to 1980, using various chemotherapy agents. Current clinical trials aim to define whether direct therapeutic injection of immunotherapy or gene therapy mediated by a viral vector can improve quality of life and overall survival [186].
At present, most early human studies perform ablation followed by surgical resection. For individuals who are clinically inoperable, endoscopic ablation may be a therapeutic option with evident benefits over the treatments that are now available. Although many ablative methods have been put forth, most of the data has come from animal research. However, there are several human studies in progress globally. We can only hope that they will overcome the myriad difficulties that this innovative technology faces, so that it can eventually be used in the real-life setting [158].

5. Conclusions

The field of diagnostic and therapeutic bronchoscopy is ever-expanding. Whenever possible, instead of proceeding with peripheral navigation, it is preferable to resort to shorter and simpler procedures, such as sampling one or more mediastinal adenopathies through endobronchial ultrasound-guided transbronchial needle aspiration. However, when it is essential to reach for a PPL, the development of smaller endoscopic devices and improved navigation systems has led to the ability to reach deep into the lung. We strongly believe that, when used in conjunction, these tools may overcome the diagnostic yield plateau and reach better results. Currently, there is not a single modality or a standardized combination of modalities to be recommended.
The desirable goal is an integration of the techniques mentioned above based on the IP expertise, the characteristics of the lesions, and the consideration of patients’ comorbidities. Furthermore, the ultimate goal for every IP should be to provide an adequate diagnosis for a PPL with its staging within a single procedure and, in the future, a radical endoscopic therapy.

Author Contributions

Conceptualization: A.F.; methodology, A.F., M.M., V.P., G.S., N.C. and E.C.; writing—original draft preparation, A.F., M.M., V.P., G.S., N.C. and E.C.; writing—review and editing, A.F., M.M., V.P., G.S., N.C. and E.C.; supervision, A.F. and E.C.; project administration, A.F. and E.C.; All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Not applicable.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Steinfort, D.P.; Khor, Y.H.; Manser, R.L.; Irving, L.B. Radial Probe Endobronchial Ultrasound for the Diagnosis of Peripheral Lung Cancer: Systematic Review and Meta-Analysis. Eur. Respir. J. 2011, 37, 902–910. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  2. Rivera, M.P.; Mehta, A.C.; Wahidi, M.M. Establishing the Diagnosis of Lung Cancer: Diagnosis and Management of Lung Cancer, 3rd Ed: American College of Chest Physicians Evidence-Based Clinical Practice Guidelines. Chest 2013, 143, e142S–e165S. [Google Scholar] [CrossRef] [PubMed]
  3. Shepherd, R.W. Bronchoscopic Pursuit of the Peripheral Pulmonary Lesion: Navigational Bronchoscopy, Radial Endobronchial Ultrasound, and Ultrathin Bronchoscopy. Curr. Opin. Pulm. Med. 2016, 22, 257–264. [Google Scholar] [CrossRef] [PubMed]
  4. Holin, S.M.; Dwork, R.E.; Glaser, S.; Rikli, A.E.; Stocklen, J.B. Solitary Pulmonary Nodules Found in a Community-Wide Chest Roentgenographic Survey; a Five-Year Follow-up Study. Am. Rev. Tuberc. 1959, 79, 427–439. [Google Scholar] [CrossRef] [PubMed]
  5. Ost, D.; Fein, A.M.; Feinsilver, S.H. Clinical Practice. The Solitary Pulmonary Nodule. N. Engl. J. Med. 2003, 348, 2535–2542. [Google Scholar] [CrossRef]
  6. Callister, M.E.J.; Baldwin, D.R.; Akram, A.R.; Barnard, S.; Cane, P.; Draffan, J.; Franks, K.; Gleeson, F.; Graham, R.; Malhotra, P.; et al. British Thoracic Society Guidelines for the Investigation and Management of Pulmonary Nodules. Thorax 2015, 70 (Suppl. 2), ii1–ii54. [Google Scholar] [CrossRef] [Green Version]
  7. National Lung Screening Trial Research Team; Aberle, D.R.; Adams, A.M.; Berg, C.D.; Black, W.C.; Clapp, J.D.; Fagerstrom, R.M.; Gareen, I.F.; Gatsonis, C.; Marcus, P.M.; et al. Reduced Lung-Cancer Mortality with Low-Dose Computed Tomographic Screening. N. Engl. J. Med. 2011, 365, 395–409. [Google Scholar] [CrossRef] [Green Version]
  8. De Koning, H.J.; van der Aalst, C.M.; de Jong, P.A.; Scholten, E.T.; Nackaerts, K.; Heuvelmans, M.A.; Lammers, J.-W.J.; Weenink, C.; Yousaf-Khan, U.; Horeweg, N.; et al. Reduced Lung-Cancer Mortality with Volume CT Screening in a Randomized Trial. N. Engl. J. Med. 2020, 382, 503–513. [Google Scholar] [CrossRef]
  9. Field, J.K.; Vulkan, D.; Davies, M.P.A.; Baldwin, D.R.; Brain, K.E.; Devaraj, A.; Eisen, T.; Gosney, J.; Green, B.A.; Holemans, J.A.; et al. Lung Cancer Mortality Reduction by LDCT Screening: UKLS Randomised Trial Results and International Meta-Analysis. Lancet Reg. Health Eur. 2021, 10, 100179. [Google Scholar] [CrossRef]
  10. Mazzone, P.J.; Silvestri, G.A.; Souter, L.H.; Caverly, T.J.; Kanne, J.P.; Katki, H.A.; Wiener, R.S.; Detterbeck, F.C. Screening for Lung Cancer: CHEST Guideline and Expert Panel Report. Chest 2021, 160, e427–e494. [Google Scholar] [CrossRef]
  11. Khan, T.; Usman, Y.; Abdo, T.; Chaudry, F.; Keddissi, J.I.; Youness, H.A. Diagnosis and Management of Peripheral Lung Nodule. Ann. Transl. Med. 2019, 7, 348. [Google Scholar] [CrossRef]
  12. Patel, V.K.; Naik, S.K.; Naidich, D.P.; Travis, W.D.; Weingarten, J.A.; Lazzaro, R.; Gutterman, D.D.; Wentowski, C.; Grosu, H.B.; Raoof, S. A Practical Algorithmic Approach to the Diagnosis and Management of Solitary Pulmonary Nodules: Part 2: Pretest Probability and Algorithm. Chest 2013, 143, 840–846. [Google Scholar] [CrossRef] [Green Version]
  13. Gould, M.K.; Ananth, L.; Barnett, P.G. Veterans Affairs SNAP Cooperative Study Group A Clinical Model to Estimate the Pretest Probability of Lung Cancer in Patients with Solitary Pulmonary Nodules. Chest 2007, 131, 383–388. [Google Scholar] [CrossRef] [Green Version]
  14. Peto, R.; Lopez, A.D.; Boreham, J.; Thun, M.; Heath, C. Mortality from Tobacco in Developed Countries: Indirect Estimation from National Vital Statistics. Lancet Lond. Engl. 1992, 339, 1268–1278. [Google Scholar] [CrossRef]
  15. Quint, L.E.; Park, C.H.; Iannettoni, M.D. Solitary Pulmonary Nodules in Patients with Extrapulmonary Neoplasms. Radiology 2000, 217, 257–261. [Google Scholar] [CrossRef]
  16. Mery, C.M.; Pappas, A.N.; Bueno, R.; Mentzer, S.J.; Lukanich, J.M.; Sugarbaker, D.J.; Jaklitsch, M.T. Relationship between a History of Antecedent Cancer and the Probability of Malignancy for a Solitary Pulmonary Nodule. Chest 2004, 125, 2175–2181. [Google Scholar] [CrossRef]
  17. Naccache, J.-M.; Gibiot, Q.; Monnet, I.; Antoine, M.; Wislez, M.; Chouaid, C.; Cadranel, J. Lung Cancer and Interstitial Lung Disease: A Literature Review. J. Thorac. Dis. 2018, 10, 3829–3844. [Google Scholar] [CrossRef]
  18. Wilson, D.O.; Weissfeld, J.L.; Balkan, A.; Schragin, J.G.; Fuhrman, C.R.; Fisher, S.N.; Wilson, J.; Leader, J.K.; Siegfried, J.M.; Shapiro, S.D.; et al. Association of Radiographic Emphysema and Airflow Obstruction with Lung Cancer. Am. J. Respir. Crit. Care Med. 2008, 178, 738–744. [Google Scholar] [CrossRef] [Green Version]
  19. Haruki, T.; Shomori, K.; Shiomi, T.; Taniguchi, Y.; Nakamura, H.; Ito, H. The Morphological Diversity of Small Lung Adenocarcinoma with Mixed Subtypes Is Associated with Local Invasiveness and Prognosis. Eur. J. Cardio-Thorac. Surg. Off. J. Eur. Assoc. Cardio-Thorac. Surg. 2011, 39, 763–768. [Google Scholar] [CrossRef] [Green Version]
  20. WHO. Thoracic Tumours. WHO Classification of Tumours, 5th ed.; WHO: Geneva, Switzerland, 2021; Volume 5, ISBN 978-92-832-4506-3.
  21. Molina, J.R.; Yang, P.; Cassivi, S.D.; Schild, S.E.; Adjei, A.A. Non–Small Cell Lung Cancer: Epidemiology, Risk Factors, Treatment, and Survivorship. Mayo Clin. Proc. Mayo Clin. 2008, 83, 584–594. [Google Scholar] [CrossRef]
  22. Funai, K.; Yokose, T.; Ishii, G.; Araki, K.; Yoshida, J.; Nishimura, M.; Nagai, K.; Nishiwaki, Y.; Ochiai, A. Clinicopathologic Characteristics of Peripheral Squamous Cell Carcinoma of the Lung. Am. J. Surg. Pathol. 2003, 27, 978–984. [Google Scholar] [CrossRef] [PubMed]
  23. Tomashefski, J.F.; Connors, A.F.; Rosenthal, E.S.; Hsiue, I.L. Peripheral vs Central Squamous Cell Carcinoma of the Lung. A Comparison of Clinical Features, Histopathology, and Survival. Arch. Pathol. Lab. Med. 1990, 114, 468–474. [Google Scholar] [PubMed]
  24. Gawrychowski, J.; Bruliński, K.; Malinowski, E.; Papla, B. Prognosis and Survival after Radical Resection of Primary Adenosquamous Lung Carcinoma. Eur. J. Cardio-Thorac. Surg. Off. J. Eur. Assoc. Cardio-Thorac. Surg. 2005, 27, 686–692. [Google Scholar] [CrossRef] [PubMed]
  25. Huhti, E.; Saloheimo, M.; Sutinen, S.; Reinilä, A. Does the Location of Lung Cancer Affect Its Prognosis? Eur. J. Respir. Dis. 1983, 64, 460–465. [Google Scholar] [PubMed]
  26. Wang, Z.; Li, M.; Teng, F.; Kong, L.; Yu, J. Primary Tumor Location Is an Important Predictor of Survival in Pulmonary Adenocarcinoma. Cancer Manag. Res. 2019, 11, 2269–2280. [Google Scholar] [CrossRef] [Green Version]
  27. Kanaji, N.; Sakai, K.; Ueda, Y.; Miyawaki, H.; Ishii, T.; Watanabe, N.; Kita, N.; Kadota, K.; Kadowaki, N.; Bandoh, S. Peripheral-Type Small Cell Lung Cancer Is Associated with Better Survival and Higher Frequency of Interstitial Lung Disease. Lung Cancer Amst. Neth. 2017, 108, 126–133. [Google Scholar] [CrossRef]
  28. Shin, S.H.; Jeong, D.Y.; Lee, K.S.; Cho, J.H.; Choi, Y.S.; Lee, K.; Um, S.-W.; Kim, H.; Jeong, B.-H. Which Definition of a Central Tumour Is More Predictive of Occult Mediastinal Metastasis in Nonsmall Cell Lung Cancer Patients with Radiological N0 Disease? Eur. Respir. J. 2019, 53, 1801508. [Google Scholar] [CrossRef]
  29. Klikovits, T.; Lohinai, Z.; Fábián, K.; Gyulai, M.; Szilasi, M.; Varga, J.; Baranya, E.; Pipek, O.; Csabai, I.; Szállási, Z.; et al. New Insights into the Impact of Primary Lung Adenocarcinoma Location on Metastatic Sites and Sequence: A Multicenter Cohort Study. Lung Cancer Amst. Neth. 2018, 126, 139–148. [Google Scholar] [CrossRef]
  30. Lin, M.-W.; Huang, Y.-L.; Yang, C.-Y.; Kuo, S.-W.; Wu, C.-T.; Chang, Y.-L. The Differences in Clinicopathologic and Prognostic Characteristics Between Surgically Resected Peripheral and Central Lung Squamous Cell Carcinoma. Ann. Surg. Oncol. 2019, 26, 217–229. [Google Scholar] [CrossRef]
  31. Yang, L.; Wang, S.; Gerber, D.E.; Zhou, Y.; Xu, F.; Liu, J.; Liang, H.; Xiao, G.; Zhou, Q.; Gazdar, A.; et al. Main Bronchus Location Is a Predictor for Metastasis and Prognosis in Lung Adenocarcinoma: A Large Cohort Analysis. Lung Cancer Amst. Neth. 2018, 120, 22–26. [Google Scholar] [CrossRef]
  32. Sun, W.; Yang, X.; Liu, Y.; Yuan, Y.; Lin, D. Primary Tumor Location Is a Useful Predictor for Lymph Node Metastasis and Prognosis in Lung Adenocarcinoma. Clin. Lung Cancer 2017, 18, e49–e55. [Google Scholar] [CrossRef]
  33. Moon, Y.; Lee, K.Y.; Sung, S.W.; Park, J.K. Differing Histopathology and Prognosis in Pulmonary Adenocarcinoma at Central and Peripheral Locations. J. Thorac. Dis. 2016, 8, 169–177. [Google Scholar] [CrossRef]
  34. Ikematsu, Y.; Izumi, M.; Takayama, K.; Kumazoe, H.; Wakamatsu, K.; Kawasaki, M. Small-Cell Lung Cancer from the Peripheral Lung Is Frequently Accompanied by Emphysema and Interstitial Lung Disease in the Background. Thorac. Cancer 2022, 13, 2616–2623. [Google Scholar] [CrossRef]
  35. Decaluwé, H.; Stanzi, A.; Dooms, C.; Fieuws, S.; Coosemans, W.; Depypere, L.; Deroose, C.M.; Dewever, W.; Nafteux, P.; Peeters, S.; et al. Central Tumour Location Should Be Considered When Comparing N1 Upstaging between Thoracoscopic and Open Surgery for Clinical Stage I Non-Small-Cell Lung Cancer. Eur. J. Cardio-Thorac. Surg. Off. J. Eur. Assoc. Cardio-Thorac. Surg. 2016, 50, 110–117. [Google Scholar] [CrossRef] [Green Version]
  36. Shi, Y.; Wu, S.; Ma, S.; Lyu, Y.; Xu, H.; Deng, L.; Chen, X. Comparison Between Wedge Resection and Lobectomy/Segmentectomy for Early-Stage Non-Small Cell Lung Cancer: A Bayesian Meta-Analysis and Systematic Review. Ann. Surg. Oncol. 2022, 29, 1868–1879. [Google Scholar] [CrossRef]
  37. Siegel, R.L.; Miller, K.D.; Jemal, A. Cancer Statistics, 2018. CA. Cancer J. Clin. 2018, 68, 7–30. [Google Scholar] [CrossRef]
  38. Infante, M.; Sestini, S.; Galeone, C.; Marchianò, A.; Lutman, F.R.; Angeli, E.; Calareso, G.; Pelosi, G.; Sozzi, G.; Silva, M.; et al. Lung Cancer Screening with Low-Dose Spiral Computed Tomography: Evidence from a Pooled Analysis of Two Italian Randomized Trials. Eur. J. Cancer Prev. Off. J. Eur. Cancer Prev. Organ. ECP 2017, 26, 324–329. [Google Scholar] [CrossRef]
  39. Baaklini, W.A.; Reinoso, M.A.; Gorin, A.B.; Sharafkaneh, A.; Manian, P. Diagnostic Yield of Fiberoptic Bronchoscopy in Evaluating Solitary Pulmonary Nodules. Chest 2000, 117, 1049–1054. [Google Scholar] [CrossRef] [Green Version]
  40. Deppen, S.A.; Davis, W.T.; Green, E.A.; Rickman, O.; Aldrich, M.C.; Fletcher, S.; Putnam, J.B.; Grogan, E.L. Cost-Effectiveness of Initial Diagnostic Strategies for Pulmonary Nodules Presenting to Thoracic Surgeons. Ann. Thorac. Surg. 2014, 98, 1214–1222. [Google Scholar] [CrossRef] [Green Version]
  41. Zhang, W.; Chen, S.; Dong, X.; Lei, P. Meta-Analysis of the Diagnostic Yield and Safety of Electromagnetic Navigation Bronchoscopy for Lung Nodules. J. Thorac. Dis. 2015, 7, 799–809. [Google Scholar] [CrossRef]
  42. Swischuk, J.L.; Castaneda, F.; Patel, J.C.; Li, R.; Fraser, K.W.; Brady, T.M.; Bertino, R.E. Percutaneous Transthoracic Needle Biopsy of the Lung: Review of 612 Lesions. J. Vasc. Interv. Radiol. JVIR 1998, 9, 347–352. [Google Scholar] [CrossRef] [PubMed]
  43. Laurent, F.; Latrabe, V.; Vergier, B.; Michel, P. Percutaneous CT-Guided Biopsy of the Lung: Comparison between Aspiration and Automated Cutting Needles Using a Coaxial Technique. Cardiovasc. Intervent. Radiol. 2000, 23, 266–272. [Google Scholar] [CrossRef] [PubMed]
  44. Klein, J.S.; Salomon, G.; Stewart, E.A. Transthoracic Needle Biopsy with a Coaxially Placed 20-Gauge Automated Cutting Needle: Results in 122 Patients. Radiology 1996, 198, 715–720. [Google Scholar] [CrossRef] [PubMed]
  45. Wallace, M.J.; Krishnamurthy, S.; Broemeling, L.D.; Gupta, S.; Ahrar, K.; Morello, F.A.; Hicks, M.E. CT-Guided Percutaneous Fine-Needle Aspiration Biopsy of Small (< or =1-Cm) Pulmonary Lesions. Radiology 2002, 225, 823–828. [Google Scholar] [CrossRef] [PubMed]
  46. Saji, H.; Nakamura, H.; Tsuchida, T.; Tsuboi, M.; Kawate, N.; Konaka, C.; Kato, H. The Incidence and the Risk of Pneumothorax and Chest Tube Placement after Percutaneous CT-Guided Lung Biopsy: The Angle of the Needle Trajectory Is a Novel Predictor. Chest 2002, 121, 1521–1526. [Google Scholar] [CrossRef] [PubMed]
  47. Kazerooni, E.A.; Lim, F.T.; Mikhail, A.; Martinez, F.J. Risk of Pneumothorax in CT-Guided Transthoracic Needle Aspiration Biopsy of the Lung. Radiology 1996, 198, 371–375. [Google Scholar] [CrossRef]
  48. Wu, C.C.; Maher, M.M.; Shepard, J.-A.O. Complications of CT-Guided Percutaneous Needle Biopsy of the Chest: Prevention and Management. AJR Am. J. Roentgenol. 2011, 196, W678–W682. [Google Scholar] [CrossRef]
  49. Geraghty, P.R.; Kee, S.T.; McFarlane, G.; Razavi, M.K.; Sze, D.Y.; Dake, M.D. CT-Guided Transthoracic Needle Aspiration Biopsy of Pulmonary Nodules: Needle Size and Pneumothorax Rate. Radiology 2003, 229, 475–481. [Google Scholar] [CrossRef]
  50. Cox, J.E.; Chiles, C.; McManus, C.M.; Aquino, S.L.; Choplin, R.H. Transthoracic Needle Aspiration Biopsy: Variables That Affect Risk of Pneumothorax. Radiology 1999, 212, 165–168. [Google Scholar] [CrossRef]
  51. Zarbo, R.J.; Fenoglio-Preiser, C.M. Interinstitutional Database for Comparison of Performance in Lung Fine-Needle Aspiration Cytology. A College of American Pathologists Q-Probe Study of 5264 Cases with Histologic Correlation. Arch. Pathol. Lab. Med. 1992, 116, 463–470. [Google Scholar]
  52. Greenspan, B.S. Role of PET/CT for Precision Medicine in Lung Cancer: Perspective of the Society of Nuclear Medicine and Molecular Imaging. Transl. Lung Cancer Res. 2017, 6, 617–620. [Google Scholar] [CrossRef] [PubMed]
  53. Kandathil, A.; Kay, F.U.; Butt, Y.M.; Wachsmann, J.W.; Subramaniam, R.M. Role of FDG PET/CT in the Eighth Edition of TNM Staging of Non-Small Cell Lung Cancer. Radiogr. Rev. Publ. Radiol. Soc. N. Am. Inc 2018, 38, 2134–2149. [Google Scholar] [CrossRef] [PubMed]
  54. MacMahon, H.; Naidich, D.P.; Goo, J.M.; Lee, K.S.; Leung, A.N.C.; Mayo, J.R.; Mehta, A.C.; Ohno, Y.; Powell, C.A.; Prokop, M.; et al. Guidelines for Management of Incidental Pulmonary Nodules Detected on CT Images: From the Fleischner Society 2017. Radiology 2017, 284, 228–243. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  55. Ali, M.S.; Sethi, J.; Taneja, A.; Musani, A.; Maldonado, F. Computed Tomography Bronchus Sign and the Diagnostic Yield of Guided Bronchoscopy for Peripheral Pulmonary Lesions. A Systematic Review and Meta-Analysis. Ann. Am. Thorac. Soc. 2018, 15, 978–987. [Google Scholar] [CrossRef] [PubMed]
  56. Ost, D.E.; Ernst, A.; Lei, X.; Kovitz, K.L.; Benzaquen, S.; Diaz-Mendoza, J.; Greenhill, S.; Toth, J.; Feller-Kopman, D.; Puchalski, J.; et al. Diagnostic Yield and Complications of Bronchoscopy for Peripheral Lung Lesions. Results of the AQuIRE Registry. Am. J. Respir. Crit. Care Med. 2016, 193, 68–77. [Google Scholar] [CrossRef] [Green Version]
  57. Sun, L.; Qin, C.; Fu, Q.; Hu, S.; Zhao, W.; Li, H. Comparison of the Detection Rates of Different Diagnostic Methods for Primary Peripheral Lung Cancer. Front. Oncol. 2021, 11, 696239. [Google Scholar] [CrossRef]
  58. Lin, C.-K.; Jan, I.-S.; Yu, K.-L.; Chang, L.-Y.; Fan, H.-J.; Wen, Y.-F.; Ho, C.-C. Rapid On-Site Cytologic Evaluation by Pulmonologist Improved Diagnostic Accuracy of Endobronchial Ultrasound-Guided Transbronchial Biopsy. J. Formos. Med. Assoc. Taiwan Yi Zhi 2020, 119, 1684–1692. [Google Scholar] [CrossRef]
  59. Yuan, M.; Wang, Y.; Yin, W.; Xiao, Y.; Hu, M.; Hu, Y. Efficacy of Rapid On-Site Cytological Evaluation (ROSE) by a Pulmonologist in Determining Specimen Adequacy and Diagnostic Accuracy in Interventional Diagnosis of Lung Lesions. J. Int. Med. Res. 2021, 49, 300060520982687. [Google Scholar] [CrossRef]
  60. Izumo, T.; Matsumoto, Y.; Sasada, S.; Chavez, C.; Nakai, T.; Tsuchida, T. Utility of Rapid On-Site Cytologic Evaluation during Endobronchial Ultrasound with a Guide Sheath for Peripheral Pulmonary Lesions. Jpn. J. Clin. Oncol. 2017, 47, 221–225. [Google Scholar] [CrossRef] [Green Version]
  61. Du Rand, I.A.; Barber, P.V.; Goldring, J.; Lewis, R.A.; Mandal, S.; Munavvar, M.; Rintoul, R.C.; Shah, P.L.; Singh, S.; Slade, M.G.; et al. British Thoracic Society Guideline for Advanced Diagnostic and Therapeutic Flexible Bronchoscopy in Adults. Thorax 2011, 66 (Suppl. 3), iii1–iii21. [Google Scholar] [CrossRef] [Green Version]
  62. Khemasuwan, D.; Teerapuncharoen, K.; Griffin, D.C. Diagnostic Yield and Safety of Bronchoscopist-Directed Moderate Sedation with a Bolus Dose Administration of Propofol During Endobronchial Ultrasound Bronchoscopy. J. Bronchol. Interv. Pulmonol. 2018, 25, 181–188. [Google Scholar] [CrossRef]
  63. Prakash, U.B. The Use of the Pediatric Fiberoptic Bronchoscope in Adults. Am. Rev. Respir. Dis. 1985, 132, 715–717. [Google Scholar] [CrossRef]
  64. Oki, M.; Saka, H. Diagnostic Value of Ultrathin Bronchoscopy in Peripheral Pulmonary Lesions: A Narrative Review. J. Thorac. Dis. 2020, 12, 7675–7682. [Google Scholar] [CrossRef]
  65. Sumi, T.; Shijubou, N.; Sawai, T.; Kamada, K.; Yamada, Y.; Nakata, H.; Mori, Y.; Chiba, H. Transbronchial Needle Aspiration with Endobronchial Ultrasonography and Ultrathin Bronchoscopy for Peripheral Pulmonary Lesions. Respir. Investig. 2021, 59, 766–771. [Google Scholar] [CrossRef]
  66. Kim, S.H.; Kim, J.; Pak, K.; Eom, J.S. Ultrathin Bronchoscopy for the Diagnosis of Peripheral Pulmonary Lesions: A Meta-Analysis. Respir. Int. Rev. Thorac. Dis. 2023, 102, 34–45. [Google Scholar] [CrossRef]
  67. Nishii, Y.; Nakamura, Y.; Fujiwara, K.; Ito, K.; Sakaguchi, T.; Suzuki, Y.; Furuhashi, K.; Kobayashi, T.; Yasuma, T.; D’Alessandro-Gabazza, C.N.; et al. Use of Ultrathin Bronchoscope on a Need Basis Improves Diagnostic Yield of Difficult-to-Approach Pulmonary Lesions. Front. Med. 2020, 7, 588048. [Google Scholar] [CrossRef]
  68. Oki, M.; Saka, H.; Ando, M.; Asano, F.; Kurimoto, N.; Morita, K.; Kitagawa, C.; Kogure, Y.; Miyazawa, T. Ultrathin Bronchoscopy with Multimodal Devices for Peripheral Pulmonary Lesions. A Randomized Trial. Am. J. Respir. Crit. Care Med. 2015, 192, 468–476. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  69. Wahidi, M.M.; Herth, F.; Yasufuku, K.; Shepherd, R.W.; Yarmus, L.; Chawla, M.; Lamb, C.; Casey, K.R.; Patel, S.; Silvestri, G.A.; et al. Technical Aspects of Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration: CHEST Guideline and Expert Panel Report. Chest 2016, 149, 816–835. [Google Scholar] [CrossRef] [Green Version]
  70. Patel, P.; Wada, H.; Hu, H.-P.; Hirohashi, K.; Kato, T.; Ujiie, H.; Ahn, J.Y.; Lee, D.; Geddie, W.; Yasufuku, K. First Evaluation of the New Thin Convex Probe Endobronchial Ultrasound Scope: A Human Ex Vivo Lung Study. Ann. Thorac. Surg. 2017, 103, 1158–1164. [Google Scholar] [CrossRef] [Green Version]
  71. Boskovic, T.; Stojanovic, M.; Stanic, J.; Pena Karan, S.; Vujasinovic, G.; Dragisic, D.; Zarogoulidis, K.; Kougioumtzi, I.; Dryllis, G.; Kioumis, I.; et al. Pneumothorax after Transbronchial Needle Biopsy. J. Thorac. Dis. 2014, 6, S427–S434. [Google Scholar] [CrossRef]
  72. Huang, Y.; Huang, H.; Li, Q.; Browning, R.F.; Parrish, S.; Turner, J.F.; Zarogoulidis, K.; Kougioumtzi, I.; Dryllis, G.; Kioumis, I.; et al. Transbronchial Lung Biopsy and Pneumothorax. J. Thorac. Dis. 2014, 6, S443–S447. [Google Scholar] [CrossRef] [PubMed]
  73. Herout, V.; Heroutova, M.; Merta, Z.; Cundrle, I.; Brat, K. Transbronchial Biopsy from the Upper Pulmonary Lobes Is Associated with Increased Risk of Pneumothorax—A Retrospective Study. BMC Pulm. Med. 2019, 19, 56. [Google Scholar] [CrossRef] [PubMed]
  74. Tanner, N.T.; Yarmus, L.; Chen, A.; Wang Memoli, J.; Mehta, H.J.; Pastis, N.J.; Lee, H.; Jantz, M.A.; Nietert, P.J.; Silvestri, G.A. Standard Bronchoscopy with Fluoroscopy vs Thin Bronchoscopy and Radial Endobronchial Ultrasound for Biopsy of Pulmonary Lesions. Chest 2018, 154, 1035–1043. [Google Scholar] [CrossRef] [PubMed]
  75. Kanodra, N.; Silvestri, G.; MD, M.; Tanner, N.; MD, M. Screening and Early Detection Efforts in Lung Cancer. Cancer 2015, 121, 1347–1356. [Google Scholar] [CrossRef] [PubMed]
  76. Ozgul, G.; Cetinkaya, E.; Ozgul, M.A.; Abul, Y.; Gencoglu, A.; Kamiloglu, E.; Gul, S.; Dincer, H.E. Efficacy and Safety of Electromagnetic Navigation Bronchoscopy with or without Radial Endobronchial Ultrasound for Peripheral Lung Lesions. Endosc. Ultrasound 2016, 5, 189–195. [Google Scholar] [CrossRef] [Green Version]
  77. Casal, R.F.; Sarkiss, M.; Jones, A.K.; Stewart, J.; Tam, A.; Grosu, H.B.; Ost, D.E.; Jimenez, C.A.; Eapen, G.A. Cone Beam Computed Tomography-Guided Thin/Ultrathin Bronchoscopy for Diagnosis of Peripheral Lung Nodules: A Prospective Pilot Study. J. Thorac. Dis. 2018, 10, 6950–6959. [Google Scholar] [CrossRef]
  78. Yoshikawa, M.; Sukoh, N.; Yamazaki, K.; Kanazawa, K.; Fukumoto, S.; Harada, M.; Kikuchi, E.; Munakata, M.; Nishimura, M.; Isobe, H. Diagnostic Value of Endobronchial Ultrasonography with a Guide Sheath for Peripheral Pulmonary Lesions without X-Ray Fluoroscopy. Chest 2007, 131, 1788–1793. [Google Scholar] [CrossRef]
  79. Jiang, L.; Xu, J.; Liu, C.; Gao, N.; Zhao, J.; Han, X.; Zhang, X.; Zhao, X.; Liu, Y.; Wang, W.; et al. Diagnosis of Peripheral Pulmonary Lesions with Transbronchial Lung Cryobiopsy by Guide Sheath and Radial Endobronchial Ultrasonography: A Prospective Control Study. Can. Respir. J. 2021, 2021, 6947037. [Google Scholar] [CrossRef]
  80. Chen, A.; Chenna, P.; Loiselle, A.; Massoni, J.; Mayse, M.; Misselhorn, D. Radial Probe Endobronchial Ultrasound for Peripheral Pulmonary Lesions. A 5-Year Institutional Experience. Ann. Am. Thorac. Soc. 2014, 11, 578–582. [Google Scholar] [CrossRef]
  81. Dhillon, S.S.; Harris, K. Bronchoscopy for the Diagnosis of Peripheral Lung Lesions. J. Thorac. Dis. 2017, 9, S1047–S1058. [Google Scholar] [CrossRef] [Green Version]
  82. Spiro, S.G.; Gould, M.K.; Colice, G.L. American College of Chest Physicians Initial Evaluation of the Patient with Lung Cancer: Symptoms, Signs, Laboratory Tests, and Paraneoplastic Syndromes: ACCP Evidenced-Based Clinical Practice Guidelines (2nd Edition). Chest 2007, 132, 149S–160S. [Google Scholar] [CrossRef]
  83. Bhadra, K.; Setser, R.M.; Condra, W.; Pritchett, M.A. Lung Navigation Ventilation Protocol to Optimize Biopsy of Peripheral Lung Lesions. J. Bronchol. Interv. Pulmonol. 2022, 29, 7–17. [Google Scholar] [CrossRef]
  84. Qi, J.-C.; Liao, L.; Zhao, Z.; Zeng, H.; Wang, T.; Hu, M.; Wang, L.; Wu, Z.; Ye, Y.; Ou, Y.; et al. Impact of Rapid On-Site Evaluation Combined with Endobronchial Ultrasound and Virtual Bronchoscopic Navigation in Diagnosing Peripheral Lung Lesions. BMC Pulm. Med. 2022, 22, 117. [Google Scholar] [CrossRef]
  85. Haoran, E.; Chen, J.; Sun, W.; Zhang, Y.; Ren, S.; Shi, J.; Wen, Y.; Su, C.; Ni, J.; Zhang, L.; et al. Three-Dimensionally Printed Navigational Template: A Promising Guiding Approach for Lung Biopsy. Transl. Lung Cancer Res. 2022, 11, 393–403. [Google Scholar] [CrossRef]
  86. Dhillon, S.S.; Dexter, E.U. Advances in Bronchoscopy for Lung Cancer. J. Carcinog. 2012, 11, 19. [Google Scholar] [CrossRef]
  87. Pritchett, M.A.; Bhadra, K.; Calcutt, M.; Folch, E. Virtual or Reality: Divergence between Preprocedural Computed Tomography Scans and Lung Anatomy during Guided Bronchoscopy. J. Thorac. Dis. 2020, 12, 1595–1611. [Google Scholar] [CrossRef]
  88. Sagar, A.-E.S.; Sabath, B.F.; Eapen, G.A.; Song, J.; Marcoux, M.; Sarkiss, M.; Arain, M.H.; Grosu, H.B.; Ost, D.E.; Jimenez, C.A.; et al. Incidence and Location of Atelectasis Developed During Bronchoscopy Under General Anesthesia: The I-LOCATE Trial. Chest 2020, 158, 2658–2666. [Google Scholar] [CrossRef]
  89. De Wever, W.; Vandecaveye, V.; Lanciotti, S.; Verschakelen, J.A. Multidetector CT-Generated Virtual Bronchoscopy: An Illustrated Review of the Potential Clinical Indications. Eur. Respir. J. 2004, 23, 776–782. [Google Scholar] [CrossRef] [Green Version]
  90. The Technology | Archimedes for Biopsy of Suspected Lung Cancer | Advice | NICE. Available online: https://www.nice.org.uk/advice/mib211/chapter/The-technology (accessed on 2 December 2022).
  91. Ramzy, J.; Travaline, J.; Thomas, J.; Basile, M.; Massetti, P.; Criner, G. Biopsy through Lung Parenchymal Lesion Using Virtual Bronchoscopy Navigation (VBN) Archimedes with EBUS Sheath Tunneling. Eur. Respir. J. 2018, 52, PA876. [Google Scholar] [CrossRef]
  92. Herth, F.J.F.; Gompelmann, D.; Hoffmann, H.; Sterman, D.; Silvestri, G.; Shah, P.; Eberhardt, R. Bronchoscopic Trans-Parenchymal Nodule Access (BTPNA)—A New Real-Time Image-Guided Approach to Accessing Solitary Pulmonary Nodules (SPNs)—First in Human Data. Eur. Respir. J. 2014, 44, 326–332. [Google Scholar]
  93. Giri, M.; Puri, A.; Wang, T.; Huang, G.; Guo, S. Virtual Bronchoscopic Navigation versus Non-Virtual Bronchoscopic Navigation Assisted Bronchoscopy for the Diagnosis of Peripheral Pulmonary Lesions: A Systematic Review and Meta-Analysis. Ther. Adv. Respir. Dis. 2021, 15, 17534666211017048. [Google Scholar] [CrossRef] [PubMed]
  94. Ishida, T.; Asano, F.; Yamazaki, K.; Shinagawa, N.; Oizumi, S.; Moriya, H.; Munakata, M.; Nishimura, M. Virtual Navigation in Japan Trial Group Virtual Bronchoscopic Navigation Combined with Endobronchial Ultrasound to Diagnose Small Peripheral Pulmonary Lesions: A Randomised Trial. Thorax 2011, 66, 1072–1077. [Google Scholar] [CrossRef] [PubMed]
  95. Asano, F.; Shinagawa, N.; Ishida, T.; Shindoh, J.; Anzai, M.; Tsuzuku, A.; Oizumi, S.; Morita, S. Virtual Bronchoscopic Navigation Combined with Ultrathin Bronchoscopy. A Randomized Clinical Trial. Am. J. Respir. Crit. Care Med. 2013, 188, 327–333. [Google Scholar] [CrossRef] [PubMed]
  96. Schwarz, Y.; Greif, J.; Becker, H.D.; Ernst, A.; Mehta, A. Real-Time Electromagnetic Navigation Bronchoscopy to Peripheral Lung Lesions Using Overlaid CT Images: The First Human Study. Chest 2006, 129, 988–994. [Google Scholar] [CrossRef] [PubMed]
  97. Leong, S.; Ju, H.; Marshall, H.; Bowman, R.; Yang, I.; Ree, A.-M.; Saxon, C.; Fong, K.M. Electromagnetic Navigation Bronchoscopy: A Descriptive Analysis. J. Thorac. Dis. 2012, 4, 173–185. [Google Scholar] [CrossRef]
  98. Kalchiem-Dekel, O.; Connolly, J.G.; Lin, I.-H.; Husta, B.C.; Adusumilli, P.S.; Beattie, J.A.; Buonocore, D.J.; Dycoco, J.; Fuentes, P.; Jones, D.R.; et al. Shape-Sensing Robotic-Assisted Bronchoscopy in the Diagnosis of Pulmonary Parenchymal Lesions. Chest 2022, 161, 572–582. [Google Scholar] [CrossRef]
  99. Eberhardt, R.; Anantham, D.; Ernst, A.; Feller-Kopman, D.; Herth, F. Multimodality Bronchoscopic Diagnosis of Peripheral Lung Lesions: A Randomized Controlled Trial. Am. J. Respir. Crit. Care Med. 2007, 176, 36–41. [Google Scholar] [CrossRef]
  100. Gex, G.; Pralong, J.A.; Combescure, C.; Seijo, L.; Rochat, T.; Soccal, P.M. Diagnostic Yield and Safety of Electromagnetic Navigation Bronchoscopy for Lung Nodules: A Systematic Review and Meta-Analysis. Respir. Int. Rev. Thorac. Dis. 2014, 87, 165–176. [Google Scholar] [CrossRef]
  101. Wang Memoli, J.S.; Nietert, P.J.; Silvestri, G.A. Meta-Analysis of Guided Bronchoscopy for the Evaluation of the Pulmonary Nodule. Chest 2012, 142, 385–393. [Google Scholar] [CrossRef] [Green Version]
  102. Khan, A.Y.; Berkowitz, D.; Krimsky, W.S.; Hogarth, D.K.; Parks, C.; Bechara, R. Safety of Pacemakers and Defibrillators in Electromagnetic Navigation Bronchoscopy. Chest 2013, 143, 75–81. [Google Scholar] [CrossRef]
  103. Magnani, A.; Balbo, P.; Facchini, E.; Occhetta, E.; Marino, P. Lack of Interference of Electromagnetic Navigation Bronchoscopy to Implanted Cardioverter-Defibrillator: In-Vivo Study. Eur. Eur. Pacing Arrhythm. Card. Electrophysiol. J. Work. Groups Card. Pacing Arrhythm. Card. Cell. Electrophysiol. Eur. Soc. Cardiol. 2014, 16, 1767–1771. [Google Scholar] [CrossRef]
  104. Simoff, M.J.; Pritchett, M.A.; Reisenauer, J.S.; Ost, D.E.; Majid, A.; Keyes, C.; Casal, R.F.; Parikh, M.S.; Diaz-Mendoza, J.; Fernandez-Bussy, S.; et al. Shape-Sensing Robotic-Assisted Bronchoscopy for Pulmonary Nodules: Initial Multicenter Experience Using the IonTM Endoluminal System. BMC Pulm. Med. 2021, 21, 322. [Google Scholar] [CrossRef]
  105. Fielding, D.I.K.; Bashirzadeh, F.; Son, J.H.; Todman, M.; Chin, A.; Tan, L.; Steinke, K.; Windsor, M.N.; Sung, A.W. First Human Use of a New Robotic-Assisted Fiber Optic Sensing Navigation System for Small Peripheral Pulmonary Nodules. Respir. Int. Rev. Thorac. Dis. 2019, 98, 142–150. [Google Scholar] [CrossRef]
  106. Benn, B.S.; Romero, A.O.; Lum, M.; Krishna, G. Robotic-Assisted Navigation Bronchoscopy as a Paradigm Shift in Peripheral Lung Access. Lung 2021, 199, 177–186. [Google Scholar] [CrossRef]
  107. Reisenauer, J.; Simoff, M.J.; Pritchett, M.A.; Ost, D.E.; Majid, A.; Keyes, C.; Casal, R.F.; Parikh, M.S.; Diaz-Mendoza, J.; Fernandez-Bussy, S.; et al. Ion: Technology and Techniques for Shape-Sensing Robotic-Assisted Bronchoscopy. Ann. Thorac. Surg. 2022, 113, 308–315. [Google Scholar] [CrossRef]
  108. Chandrika, S.; Yarmus, L. Recent Developments in Advanced Diagnostic Bronchoscopy. Eur. Respir. Rev. 2020, 29, 190184. [Google Scholar] [CrossRef]
  109. Yi, L.; Peng, Z.; Chen, Z.; Tao, Y.; Lin, Z.; He, A.; Jin, M.; Peng, Y.; Zhong, Y.; Yan, H.; et al. Identification of Pulmonary Adenocarcinoma and Benign Lesions in Isolated Solid Lung Nodules Based on a Nomogram of Intranodal and Perinodal CT Radiomic Features. Front. Oncol. 2022, 12, 924055. [Google Scholar] [CrossRef]
  110. Zhang, X.; Lv, F.; Fu, B.; Li, W.; Lin, R.; Chu, Z. Clinical and Computed Tomography Characteristics for Early Diagnosis of Peripheral Small-Cell Lung Cancer. Cancer Manag. Res. 2022, 14, 589–601. [Google Scholar] [CrossRef]
  111. Setser, R.; Chintalapani, G.; Bhadra, K.; Casal, R.F. Cone Beam CT Imaging for Bronchoscopy: A Technical Review. J. Thorac. Dis. 2020, 12, 7416–7428. [Google Scholar] [CrossRef]
  112. Verhoeven, R.L.J.; Fütterer, J.J.; Hoefsloot, W.; van der Heijden, E.H.F.M. Cone-Beam CT Image Guidance with and Without Electromagnetic Navigation Bronchoscopy for Biopsy of Peripheral Pulmonary Lesions. J. Bronchol. Interv. Pulmonol. 2021, 28, 60–69. [Google Scholar] [CrossRef]
  113. Hohenforst-Schmidt, W.; Zarogoulidis, P.; Vogl, T.; Turner, J.F.; Browning, R.; Linsmeier, B.; Huang, H.; Li, Q.; Darwiche, K.; Freitag, L.; et al. Cone Beam Computertomography (CBCT) in Interventional Chest Medicine—High Feasibility for Endobronchial Realtime Navigation. J. Cancer 2014, 5, 231–241. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  114. Verhoeven, R.L.J.; Vos, S.; van der Heijden, E.H.F.M. Multi-Modal Tissue Sampling in Cone Beam CT Guided Navigation Bronchoscopy: Comparative Accuracy of Different Sampling Tools and Rapid on-Site Evaluation of Cytopathology. J. Thorac. Dis. 2021, 13, 4396–4406. [Google Scholar] [CrossRef] [PubMed]
  115. DiBardino, D.M.; Kim, R.Y.; Cao, Y.; Andronov, M.; Lanfranco, A.R.; Haas, A.R.; Vachani, A.; Ma, K.C.; Hutchinson, C.T. Diagnostic Yield of Cone-Beam-Derived Augmented Fluoroscopy and Ultrathin Bronchoscopy Versus Conventional Navigational Bronchoscopy Techniques. J. Bronchol. Interv. Pulmonol. 2022. [Google Scholar] [CrossRef] [PubMed]
  116. Hohenforst-Schmidt, W.; Banckwitz, R.; Zarogoulidis, P.; Vogl, T.; Darwiche, K.; Goldberg, E.; Huang, H.; Simoff, M.; Li, Q.; Browning, R.; et al. Radiation Exposure of Patients by Cone Beam CT during Endobronchial Navigation—A Phantom Study. J. Cancer 2014, 5, 192–202. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  117. Podder, S.; Chaudry, S.; Singh, H.; Jondall, E.M.; Kurman, J.S.; Benn, B.S. Efficacy and Safety of Cone-Beam CT Augmented Electromagnetic Navigation Guided Bronchoscopic Biopsies of Indeterminate Pulmonary Nodules. Tomogr. Ann Arbor Mich 2022, 8, 2049–2058. [Google Scholar] [CrossRef]
  118. Duke, J.D.; Fernandez-Bussy, S.; Reisenauer, J. Combined Portable Cone Beam Computed Tomography and Robotic-Assisted Bronchoscopy Impacting Diagnosis of a Solitary Pulmonary Nodule: A Case Report. AME Case Rep. 2022, 6, 23. [Google Scholar] [CrossRef]
  119. Verhoeven, R.L.J.; van der Sterren, W.; Kong, W.; Langereis, S.; van der Tol, P.; van der Heijden, E.H.F.M. Cone-Beam CT and Augmented Fluoroscopy-Guided Navigation Bronchoscopy: Radiation Exposure and Diagnostic Accuracy Learning Curves. J. Bronchol. Interv. Pulmonol. 2021, 28, 262–271. [Google Scholar] [CrossRef]
  120. Cicenia, J.; Bhadra, K.; Sethi, S.; Nader, D.A.; Whitten, P.; Hogarth, D.K. Augmented Fluoroscopy: A New and Novel Navigation Platform for Peripheral Bronchoscopy. J. Bronchol. Interv. Pulmonol. 2021, 28, 116–123. [Google Scholar] [CrossRef]
  121. Pritchett, M.A.; Schampaert, S.; de Groot, J.A.H.; Schirmer, C.C.; van der Bom, I. Cone-Beam CT With Augmented Fluoroscopy Combined With Electromagnetic Navigation Bronchoscopy for Biopsy of Pulmonary Nodules. J. Bronchol. Interv. Pulmonol. 2018, 25, 274–282. [Google Scholar] [CrossRef]
  122. Pertzov, B.; Gershman, E.; Izhakian, S.; Heching, M.; Amor, S.M.; Rosengarten, D.; Kramer, M.R. The LungVision Navigational Platform for Peripheral Lung Nodule Biopsy and the Added Value of Cryobiopsy. Thorac. Cancer 2021, 12, 2007–2012. [Google Scholar] [CrossRef]
  123. Yu, K.-L.; Yang, S.-M.; Ko, H.-J.; Tsai, H.-Y.; Ko, J.-C.; Lin, C.-K.; Ho, C.-C.; Shih, J.-Y. Efficacy and Safety of Cone-Beam Computed Tomography-Derived Augmented Fluoroscopy Combined with Endobronchial Ultrasound in Peripheral Pulmonary Lesions. Respir. Int. Rev. Thorac. Dis. 2021, 100, 538–546. [Google Scholar] [CrossRef]
  124. Singer, E.; Kneuertz, P.J.; D’Souza, D.M.; Moffatt-Bruce, S.D.; Merritt, R.E. Understanding the Financial Cost of Robotic Lobectomy: Calculating the Value of Innovation? Ann. Cardiothorac. Surg. 2019, 8, 194–201. [Google Scholar] [CrossRef]
  125. Kneuertz, P.J.; Singer, E.; D’Souza, D.M.; Abdel-Rasoul, M.; Moffatt-Bruce, S.D.; Merritt, R.E. Hospital Cost and Clinical Effectiveness of Robotic-Assisted versus Video-Assisted Thoracoscopic and Open Lobectomy: A Propensity Score-Weighted Comparison. J. Thorac. Cardiovasc. Surg. 2019, 157, 2018–2026.e2. [Google Scholar] [CrossRef] [Green Version]
  126. Lu, M.; Nath, S.; Semaan, R.W. A Review of Robotic-Assisted Bronchoscopy Platforms in the Sampling of Peripheral Pulmonary Lesions. J. Clin. Med. 2021, 10, 5678. [Google Scholar] [CrossRef]
  127. Fernandez-Bussy, S.; Abia-Trujillo, D.; Patel, N.M.; Pascual, J.M.; Majid, A.; Folch, E.E.; Reisenauer, J.S. Precautionary Strategy for High-Risk Airway Bleeding Cases during Robotic-Assisted Bronchoscopy. Respirol. Case Rep. 2021, 9, e00794. [Google Scholar] [CrossRef]
  128. Fernandez-Bussy, S.; Abia-Trujillo, D.; Majid, A.; Folch, E.E.; Patel, N.M.; Herth, F.J.F.; Reisenauer, J.S. Management of Significant Airway Bleeding during Robotic Assisted Bronchoscopy: A Tailored Approach. Respir. Int. Rev. Thorac. Dis. 2021, 100, 547–550. [Google Scholar] [CrossRef]
  129. Hassan, T.; Piton, N.; Lachkar, S.; Salaün, M.; Thiberville, L. A Novel Method for In Vivo Imaging of Solitary Lung Nodules Using Navigational Bronchoscopy and Confocal Laser Microendoscopy. Lung 2015, 193, 773–778. [Google Scholar] [CrossRef] [Green Version]
  130. Hassan, T.; Thiberville, L.; Hermant, C.; Lachkar, S.; Piton, N.; Guisier, F.; Salaun, M. Assessing the Feasibility of Confocal Laser Endomicroscopy in Solitary Pulmonary Nodules for Different Part of the Lungs, Using Either 0.6 or 1.4 Mm Probes. PloS One 2017, 12, e0189846. [Google Scholar] [CrossRef] [Green Version]
  131. Sorokina, A.; Danilevskaya, O.; Averyanov, A.; Zabozlaev, F.; Sazonov, D.; Yarmus, L.; Lee, H.J. Comparative Study of Ex Vivo Probe-Based Confocal Laser Endomicroscopy and Light Microscopy in Lung Cancer Diagnostics. Respirol. Carlton Vic 2014, 19, 907–913. [Google Scholar] [CrossRef] [PubMed]
  132. Wellikoff, A.S.; Holladay, R.C.; Downie, G.H.; Chaudoir, C.S.; Brandi, L.; Turbat-Herrera, E.A. Comparison of in Vivo Probe-Based Confocal Laser Endomicroscopy with Histopathology in Lung Cancer: A Move toward Optical Biopsy. Respirol. Carlton Vic 2015, 20, 967–974. [Google Scholar] [CrossRef]
  133. Takemura, M.; Kurimoto, N.; Hoshikawa, M.; Maeno, T.; Hisada, T.; Kurabayashi, M.; Inoue, T.; Miyazawa, T.; Mineshita, M. Probe-Based Confocal Laser Endomicroscopy for Rapid on-Site Evaluation of Transbronchial Biopsy Specimens. Thorac. Cancer 2019, 10, 1441–1447. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  134. Goorsenberg, A.; Kalverda, K.A.; Annema, J.; Bonta, P. Advances in Optical Coherence Tomography and Confocal Laser Endomicroscopy in Pulmonary Diseases. Respir. Int. Rev. Thorac. Dis. 2020, 99, 190–205. [Google Scholar] [CrossRef] [PubMed]
  135. Pahlevaninezhad, H.; Lee, A.M.; Ritchie, A.; Shaipanich, T.; Zhang, W.; Ionescu, D.N.; Hohert, G.; MacAulay, C.; Lam, S.; Lane, P. Endoscopic Doppler Optical Coherence Tomography and Autofluorescence Imaging of Peripheral Pulmonary Nodules and Vasculature. Biomed. Opt. Express 2015, 6, 4191–4199. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  136. Ding, M.; Pan, S.-Y.; Huang, J.; Yuan, C.; Zhang, Q.; Zhu, X.-L.; Cai, Y. Optical Coherence Tomography for Identification of Malignant Pulmonary Nodules Based on Random Forest Machine Learning Algorithm. PloS One 2021, 16, e0260600. [Google Scholar] [CrossRef] [PubMed]
  137. Remon, J.; Soria, J.-C.; Peters, S.; ESMO Guidelines Committee. Electronic address: [email protected] Early and Locally Advanced Non-Small-Cell Lung Cancer: An Update of the ESMO Clinical Practice Guidelines Focusing on Diagnosis, Staging, Systemic and Local Therapy. Ann. Oncol. Off. J. Eur. Soc. Med. Oncol. 2021, 32, 1637–1642. [Google Scholar] [CrossRef]
  138. Lembicz, M.; Gabryel, P.; Brajer-Luftmann, B.; Dyszkiewicz, W.; Batura-Gabryel, H. Comorbidities with Non-Small Cell Lung Cancer: Is There an Interdisciplinary Consensus Needed to Qualify Patients for Surgical Treatment? Ann. Thorac. Med. 2018, 13, 101–107. [Google Scholar] [CrossRef]
  139. Belot, A.; Fowler, H.; Njagi, E.N.; Luque-Fernandez, M.-A.; Maringe, C.; Magadi, W.; Exarchakou, A.; Quaresma, M.; Turculet, A.; Peake, M.D.; et al. Association between Age, Deprivation and Specific Comorbid Conditions and the Receipt of Major Surgery in Patients with Non-Small Cell Lung Cancer in England: A Population-Based Study. Thorax 2019, 74, 51–59. [Google Scholar] [CrossRef] [Green Version]
  140. Suzuki, S.; Goto, T. Role of Surgical Intervention in Unresectable Non-Small Cell Lung Cancer. J. Clin. Med. 2020, 9, 3881. [Google Scholar] [CrossRef]
  141. Dickhoff, C.; Dahele, M.; Paul, M.A.; van de Ven, P.M.; de Langen, A.J.; Senan, S.; Smit, E.F.; Hartemink, K.J. Salvage Surgery for Locoregional Recurrence or Persistent Tumor after High Dose Chemoradiotherapy for Locally Advanced Non-Small Cell Lung Cancer. Lung Cancer Amst. Neth. 2016, 94, 108–113. [Google Scholar] [CrossRef]
  142. Sonobe, M.; Yutaka, Y.; Nakajima, D.; Hamaji, M.; Menju, T.; Ohsumi, A.; Chen-Yoshikawa, T.F.; Sato, T.; Date, H. Salvage Surgery After Chemotherapy or Chemoradiotherapy for Initially Unresectable Lung Carcinoma. Ann. Thorac. Surg. 2019, 108, 1664–1670. [Google Scholar] [CrossRef]
  143. Ding, R.; Zhu, D.; He, P.; Ma, Y.; Chen, Z.; Shi, X. Comorbidity in Lung Cancer Patients and Its Association with Medical Service Cost and Treatment Choice in China. BMC Cancer 2020, 20, 250. [Google Scholar] [CrossRef]
  144. Leduc, C.; Antoni, D.; Charloux, A.; Falcoz, P.-E.; Quoix, E. Comorbidities in the Management of Patients with Lung Cancer. Eur. Respir. J. 2017, 49, 1601721. [Google Scholar] [CrossRef]
  145. Shibazaki, T.; Odaka, M.; Noda, Y.; Tsukamoto, Y.; Mori, S.; Asano, H.; Yamashita, M.; Morikawa, T. Effect of Comorbidities on Long-Term Outcomes after Thoracoscopic Surgery for Stage I Non-Small Cell Lung Cancer Patients with Chronic Obstructive Pulmonary Disease. J. Thorac. Dis. 2018, 10, 909–919. [Google Scholar] [CrossRef] [Green Version]
  146. Lüchtenborg, M.; Jakobsen, E.; Krasnik, M.; Linklater, K.M.; Mellemgaard, A.; Møller, H. The Effect of Comorbidity on Stage-Specific Survival in Resected Non-Small Cell Lung Cancer Patients. Eur. J. Cancer Oxf. Engl. 1990 2012, 48, 3386–3395. [Google Scholar] [CrossRef]
  147. Bral, S.; Gevaert, T.; Linthout, N.; Versmessen, H.; Collen, C.; Engels, B.; Verdries, D.; Everaert, H.; Christian, N.; De Ridder, M.; et al. Prospective, Risk-Adapted Strategy of Stereotactic Body Radiotherapy for Early-Stage Non-Small-Cell Lung Cancer: Results of a Phase II Trial. Int. J. Radiat. Oncol. Biol. Phys. 2011, 80, 1343–1349. [Google Scholar] [CrossRef]
  148. Kimura, T.; Fujiwara, T.; Kameoka, T.; Adachi, Y.; Kariya, S. Stereotactic Body Radiation Therapy for Metastatic Lung Metastases. Jpn. J. Radiol. 2022, 40, 995–1005. [Google Scholar] [CrossRef]
  149. Casutt, A.; Kinj, R.; Ozsahin, E.-M.; von Garnier, C.; Lovis, A. Fiducial Markers for Stereotactic Lung Radiation Therapy: Review of the Transthoracic, Endovascular and Endobronchial Approaches. Eur. Respir. Rev. Off. J. Eur. Respir. Soc. 2022, 31, 210149. [Google Scholar] [CrossRef]
  150. Fakiris, A.J.; McGarry, R.C.; Yiannoutsos, C.T.; Papiez, L.; Williams, M.; Henderson, M.A.; Timmerman, R. Stereotactic Body Radiation Therapy for Early-Stage Non-Small-Cell Lung Carcinoma: Four-Year Results of a Prospective Phase II Study. Int. J. Radiat. Oncol. Biol. Phys. 2009, 75, 677–682. [Google Scholar] [CrossRef]
  151. Harris, K.; Puchalski, J.; Sterman, D. Recent Advances in Bronchoscopic Treatment of Peripheral Lung Cancers. Chest 2017, 151, 674–685. [Google Scholar] [CrossRef] [Green Version]
  152. Hyun, K.; Park, I.K.; Song, J.W.; Park, S.; Kang, C.H.; Kim, Y.T. Electromagnetic Navigation Bronchoscopic Dye Marking for Localization of Small Subsolid Nodules: Retrospective Observational Study. Medicine 2019, 98, e14831. [Google Scholar] [CrossRef]
  153. Bowling, M.R.; Folch, E.E.; Khandhar, S.J.; Arenberg, D.A.; Awais, O.; Minnich, D.J.; Pritchett, M.A.; Rickman, O.B.; Sztejman, E.; Anciano, C.J. Pleural Dye Marking of Lung Nodules by Electromagnetic Navigation Bronchoscopy. Clin. Respir. J. 2019, 13, 700–707. [Google Scholar] [CrossRef] [PubMed]
  154. Lachkar, S.; Baste, J.-M.; Thiberville, L.; Peillon, C.; Rinieri, P.; Piton, N.; Guisier, F.; Salaun, M. Pleural Dye Marking Using Radial Endobronchial Ultrasound and Virtual Bronchoscopy before Sublobar Pulmonary Resection for Small Peripheral Nodules. Respir. Int. Rev. Thorac. Dis. 2018, 95, 354–361. [Google Scholar] [CrossRef] [PubMed]
  155. Muñoz-Largacha, J.A.; Ebright, M.I.; Litle, V.R.; Fernando, H.C. Electromagnetic Navigational Bronchoscopy with Dye Marking for Identification of Small Peripheral Lung Nodules during Minimally Invasive Surgical Resection. J. Thorac. Dis. 2017, 9, 802–808. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  156. Steinfort, D.P.; Siva, S.; Kron, T.; Chee, R.R.; Ruben, J.D.; Ball, D.L.; Irving, L.B. Multimodality Guidance for Accurate Bronchoscopic Insertion of Fiducial Markers. J. Thorac. Oncol. Off. Publ. Int. Assoc. Study Lung Cancer 2015, 10, 324–330. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  157. Hagmeyer, L.; Priegnitz, C.; Kocher, M.; Schilcher, B.; Budach, W.; Treml, M.; Stieglitz, S.; Randerath, W. Fiducial Marker Placement via Conventional or Electromagnetic Navigation Bronchoscopy (ENB): An Interdisciplinary Approach to the Curative Management of Lung Cancer. Clin. Respir. J. 2016, 10, 291–297. [Google Scholar] [CrossRef]
  158. Sabath, B.F.; Casal, R.F. Bronchoscopic Ablation of Peripheral Lung Tumors. J. Thorac. Dis. 2019, 11, 2628–2638. [Google Scholar] [CrossRef]
  159. Krimsky, W.S.; Minnich, D.J.; Cattaneo, S.M.; Sarkar, S.A.; Harley, D.P.; Finley, D.J.; Browning, R.F.; Parrish, S.C. Thoracoscopic Detection of Occult Indeterminate Pulmonary Nodules Using Bronchoscopic Pleural Dye Marking. J. Community Hosp. Intern. Med. Perspect. 2014, 4, 23084. [Google Scholar] [CrossRef] [Green Version]
  160. Awais, O.; Reidy, M.R.; Mehta, K.; Bianco, V.; Gooding, W.E.; Schuchert, M.J.; Luketich, J.D.; Pennathur, A. Electromagnetic Navigation Bronchoscopy-Guided Dye Marking for Thoracoscopic Resection of Pulmonary Nodules. Ann. Thorac. Surg. 2016, 102, 223–229. [Google Scholar] [CrossRef] [Green Version]
  161. Marino, K.A.; Sullivan, J.L.; Weksler, B. Electromagnetic Navigation Bronchoscopy for Identifying Lung Nodules for Thoracoscopic Resection. Ann. Thorac. Surg. 2016, 102, 454–457. [Google Scholar] [CrossRef] [Green Version]
  162. Song, J.W.; Park, I.K.; Bae, S.Y.; Na, K.J.; Park, S.; Kang, C.H.; Kim, Y.T. Electromagnetic Navigation Bronchoscopy-Guided Dye Marking for Localization of Pulmonary Nodules. Ann. Thorac. Surg. 2022, 113, 1663–1669. [Google Scholar] [CrossRef]
  163. Sullivan, J.L.; Martin, M.G.; Weksler, B. Navigational Bronchoscopy-Guided Dye Marking to Assist Resection of a Small Lung Nodule. J. Vis. Surg. 2017, 3, 131. [Google Scholar] [CrossRef] [Green Version]
  164. Zhang, J.; He, J.; Chen, J.; Zhong, Y.; He, J.; Li, S. Application of Indocyanine Green Injection Guided by Electromagnetic Navigation Bronchoscopy in Localization of Pulmonary Nodules. Transl. Lung Cancer Res. 2021, 10, 4414–4422. [Google Scholar] [CrossRef]
  165. Anayama, T.; Hirohashi, K.; Miyazaki, R.; Okada, H.; Kawamoto, N.; Yamamoto, M.; Sato, T.; Orihashi, K. Near-Infrared Dye Marking for Thoracoscopic Resection of Small-Sized Pulmonary Nodules: Comparison of Percutaneous and Bronchoscopic Injection Techniques. J. Cardiothorac. Surg. 2018, 13, 5. [Google Scholar] [CrossRef] [Green Version]
  166. Belanger, A.R.; Burks, A.C.; Chambers, D.M.; Ghosh, S.; MacRosty, C.R.; Conterato, A.J.; Rivera, M.P.; Akulian, J.A. Peripheral Lung Nodule Diagnosis and Fiducial Marker Placement Using a Novel Tip-Tracked Electromagnetic Navigation Bronchoscopy System. J. Bronchol. Interv. Pulmonol. 2019, 26, 41–48. [Google Scholar] [CrossRef]
  167. Rong, Y.; Bazan, J.G.; Sekhon, A.; Haglund, K.; Xu-Welliver, M.; Williams, T. Minimal Inter-Fractional Fiducial Migration during Image-Guided Lung Stereotactic Body Radiotherapy Using SuperLock Nitinol Coil Fiducial Markers. PloS One 2015, 10, e0131945. [Google Scholar] [CrossRef] [Green Version]
  168. Aboudara, M.; Rickman, O.; Maldonado, F. Therapeutic Bronchoscopic Techniques Available to the Pulmonologist: Emerging Therapies in the Treatment of Peripheral Lung Lesions and Endobronchial Tumors. Clin. Chest Med. 2020, 41, 145–160. [Google Scholar] [CrossRef]
  169. Tsushima, K.; Koizumi, T.; Tanabe, T.; Nakagawa, R.; Yoshikawa, S.; Yasuo, M.; Kubo, K. Bronchoscopy-Guided Radiofrequency Ablation as a Potential Novel Therapeutic Tool. Eur. Respir. J. 2007, 29, 1193–1200. [Google Scholar] [CrossRef]
  170. Xie, F.; Zheng, X.; Xiao, B.; Han, B.; Herth, F.J.F.; Sun, J. Navigation Bronchoscopy-Guided Radiofrequency Ablation for Nonsurgical Peripheral Pulmonary Tumors. Respir. Int. Rev. Thorac. Dis. 2017, 94, 293–298. [Google Scholar] [CrossRef]
  171. Fernando, H.C. Radiofrequency Ablation to Treat Non-Small Cell Lung Cancer and Pulmonary Metastases. Ann. Thorac. Surg. 2008, 85, S780–S784. [Google Scholar] [CrossRef]
  172. Bao, F.; Yu, F.; Wang, R.; Chen, C.; Zhang, Y.; Lin, B.; Wang, Y.; Hao, X.; Gu, Z.; Fang, W. Electromagnetic Bronchoscopy Guided Microwave Ablation for Early Stage Lung Cancer Presenting as Ground Glass Nodule. Transl. Lung Cancer Res. 2021, 10, 3759–3770. [Google Scholar] [CrossRef]
  173. Belfiore, G.; Ronza, F.; Belfiore, M.P.; Serao, N.; di Ronza, G.; Grassi, R.; Rotondo, A. Patients’ Survival in Lung Malignancies Treated by Microwave Ablation: Our Experience on 56 Patients. Eur. J. Radiol. 2013, 82, 177–181. [Google Scholar] [CrossRef] [PubMed]
  174. Ghosh, S.; Mehta, A.C.; Abuquyyas, S.; Raju, S.; Farver, C. Primary Lung Neoplasms Presenting as Multiple Synchronous Lung Nodules. Eur. Respir. Rev. Off. J. Eur. Respir. Soc. 2020, 29, 190142. [Google Scholar] [CrossRef] [PubMed]
  175. Giraldo Ospina, C.F.; Mongil Poce, R.; Arrabal Sánchez, R.; Medina Sánchez, R.; Sánchez Martin, N.; Gonzalez Rivas, D. Subxiphoid Uniportal Video-Assisted Bilateral Surgery: Right Upper Lobectomy and Left Upper Wedge Resection S3. J. Vis. Surg. 2017, 3, 186. [Google Scholar] [CrossRef] [PubMed]
  176. Siu, I.C.H.; Chan, J.W.Y.; Ii, T.B.M.; Ngai, J.C.L.; Lau, R.W.H.; Ng, C.S.H. Bronchoscopic Ablation of Lung Tumours: Patient Selection and Technique. J. Vis. Surg. 2022, 8, 36. [Google Scholar] [CrossRef]
  177. Moghissi, K.; Dixon, K. Is Bronchoscopic Photodynamic Therapy a Therapeutic Option in Lung Cancer? Eur. Respir. J. 2003, 22, 535–541. [Google Scholar] [CrossRef] [Green Version]
  178. Bansal, S.; Bechara, R.I.; Patel, J.D.; Mehta, H.J.; Ferguson, J.S.; Witt, B.L.; Murgu, S.D.; Yasufuku, K.; Casal, R.F. Safety and Feasibility of Photodynamic Therapy for Ablation of Peripheral Lung Tumors. J. Bronchol. Interv. Pulmonol. 2022. [Google Scholar] [CrossRef]
  179. Chang, H.; Liao, K.S.; Hsieh, Y.-S. Bronchoscopic Light Delivery Method for Peripheral Lung Cancer Photodynamic Therapy. J. Thorac. Dis. 2020, 12, 3611–3621. [Google Scholar] [CrossRef]
  180. Harms, W.; Krempien, R.; Grehn, C.; Hensley, F.; Debus, J.; Becker, H.D. Electromagnetically Navigated Brachytherapy as a New Treatment Option for Peripheral Pulmonary Tumors. Strahlenther. Onkol. Organ Dtsch. Rontgengesellschaft Al 2006, 182, 108–111. [Google Scholar] [CrossRef]
  181. Zheng, X.; Yang, C.; Zhang, X.; Yuan, H.; Xie, F.; Li, Y.; Xu, B.; Herth, F.J.F.; Sun, J. The Cryoablation for Peripheral Pulmonary Lesions Using a Novel Flexible Bronchoscopic Cryoprobe in the Ex Vivo Pig Lung and Liver. Respir. Int. Rev. Thorac. Dis. 2019, 97, 457–462. [Google Scholar] [CrossRef]
  182. Steinfort, D.P.; Herth, F.J.F. Bronchoscopic Treatments for Early-Stage Peripheral Lung Cancer: Are We Ready for Prime Time? Respirol. Carlton Vic 2020, 25, 944–952. [Google Scholar] [CrossRef]
  183. Vergnon, J.-M.; Huber, R.M.; Moghissi, K. Place of Cryotherapy, Brachytherapy and Photodynamic Therapy in Therapeutic Bronchoscopy of Lung Cancers. Eur. Respir. J. 2006, 28, 200–218. [Google Scholar] [CrossRef]
  184. Casal, R.F.; Walsh, G.; McArthur, M.; Hill, L.R.; Landaeta, M.F.; Armas Villalba, A.J.; Ong, P.; Debiane, L.; Vakil, E.; Grosu, H.B.; et al. Bronchoscopic Laser Interstitial Thermal Therapy: An Experimental Study in Normal Porcine Lung Parenchyma. J. Bronchol. Interv. Pulmonol. 2018, 25, 322–329. [Google Scholar] [CrossRef]
  185. Steinfort, D.P.; Christie, M.; Antippa, P.; Rangamuwa, K.; Padera, R.; Müller, M.R.; Irving, L.B.; Valipour, A. Bronchoscopic Thermal Vapour Ablation for Localized Cancer Lesions of the Lung: A Clinical Feasibility Treat-and-Resect Study. Respir. Int. Rev. Thorac. Dis. 2021, 100, 432–442. [Google Scholar] [CrossRef]
  186. DeMaio, A.; Sterman, D. Bronchoscopic Intratumoural Therapies for Non-Small Cell Lung Cancer. Eur. Respir. Rev. Off. J. Eur. Respir. Soc. 2020, 29, 200028. [Google Scholar] [CrossRef]
Table 1. Comparison of navigation technologies for PPLs.
Table 1. Comparison of navigation technologies for PPLs.
MethodAdvantagesDisadvantages
Ultrathin bronchoscopy
  • Affordable
  • Easily introduced into an already-established clinical practice
  • Operator-dependent tip stability
  • Small working channel
RP-EBUS
  • Affordable
  • Easily introduced into an already-established clinical practice
  • Need to interpret artifacts
  • No real-time guidance during sampling
Virtual navigation bronchoscopy
  • Active navigation correction according to preprocedural planning
  • BTPNA
  • CT-to-body divergence
  • Absence of real-time position correction by fluoroscopy
EMN
  • Active navigation correction according to preprocedural planning
  • Ability to associate real-time navigation correction with fluoroscopy
  • Real-time guidance during sampling
  • CT-to-body divergence
  • Interference with metallic objects and other magnetic fields
Shape-sensing navigation
  • Operator-independent tip stability
  • Expensive in terms of acquisition (at present only within robotic bronchoscopy technology)
Augmented fluoroscopy
  • Real-time navigation correction with fluoroscopy
  • Expensive in terms of acquisition
CBCT
  • The gold standard for tool-in-lesion confirmation
  • Expensive in terms of acquisition
  • Non-negligible radiation exposure
Robotic bronchoscopy
  • Integration of a navigation system within an articulating catheter that can be used for multiple purposes
  • Expensive both in terms of acquisition and consumables
  • Technical demanding
  • Requires general anesthesia
  • CT-to-body divergence
RP-EBUS, radial-probe endobronchial ultrasound; BTPNA, bronchial transparenchymal nodule access; EMN, electromagnetic navigation; CBCT, cone-beam computed tomography.
Table 2. Ablation technologies for PPLs and related mechanisms of action.
Table 2. Ablation technologies for PPLs and related mechanisms of action.
MethodMechanism of Action
RFAElectromagnetic-induced selective heat damage
MWAMicrowave-induced selective heat damage
PDTOxidative damage by a photosensitizing agent
BrachytherapySelective, high-dose radiation exposure
CryoablationFreezing-induced cytotoxicity and delayed cell apoptosis
BLITTHeat-induced damage and charring
Thermal vapor ablationVapor-induced regional heat damage
Intralesional therapeutic drugsDirect injection of an antineoplastic drug
RFA, radiofrequency ablation; MWA, microwave ablation; PDT, photodynamic therapy; BLITT, bronchoscopic laser interstitial thermal therapy; AEs, adverse events.
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Fantin, A.; Manera, M.; Patruno, V.; Sartori, G.; Castaldo, N.; Crisafulli, E. Endoscopic Technologies for Peripheral Pulmonary Lesions: From Diagnosis to Therapy. Life 2023, 13, 254. https://doi.org/10.3390/life13020254

AMA Style

Fantin A, Manera M, Patruno V, Sartori G, Castaldo N, Crisafulli E. Endoscopic Technologies for Peripheral Pulmonary Lesions: From Diagnosis to Therapy. Life. 2023; 13(2):254. https://doi.org/10.3390/life13020254

Chicago/Turabian Style

Fantin, Alberto, Massimiliano Manera, Vincenzo Patruno, Giulia Sartori, Nadia Castaldo, and Ernesto Crisafulli. 2023. "Endoscopic Technologies for Peripheral Pulmonary Lesions: From Diagnosis to Therapy" Life 13, no. 2: 254. https://doi.org/10.3390/life13020254

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop