Dental Materials Journal
Online ISSN : 1881-1361
Print ISSN : 0287-4547
ISSN-L : 0287-4547
Anisotropy of Tensile Strengths of Bovine Dentin Regarding Dentinal Tubule Orientation and Location
Toshiko INOUEHidekazu TAKAHASHIFumio NISHIMURA
Author information
JOURNAL FREE ACCESS

2002 Volume 21 Issue 1 Pages 32-43

Details
Abstract

The purpose of this study was to investigate the effects of the location and orientation of dentinal tubules in the tooth on tensile strengths of the dentin. Dumbbell-shaped specimens of 12 groups from various locations and dentinal tubule orientations were prepared. The tensile test was performed in distilled water at a temperature of 37°C. The tensile strengths of the parallel to the orientation were significantly greater than those of the perpendicular to the orientation; the tensile strengths of the radicular dentin were significantly greater than those of the coronal dentin. Nevertheless, in the radicular dentin, the tensile strengths of the perpendicular to dentinal tubules differ with respect to tensile forces. These results suggest that tensile strength of the dentin varies according to the location and orientation of dentinal tubules in the tooth.

Content from these authors
© The Japanese Society for Dental Materials and Devices
Previous article Next article
feedback
Top