A Review on the New Structure of Savonius Wind Turbines

Article Preview

Abstract:

This paper summarizes the research results of the structural parameters which have effects on the performance of Savonius wind turbine. Savonius wind turbine being used in wind power and tidal power belongs to vertical axis wind turbine (VAWT). Recently, more and more research have placed on it for its advantages such as: being able to accept wind from any direction, long fatigue life of the blades, high starting torque, wide working wind speed range, easy to install, manufacture and maintain and low noise etc. The performance of Savonius wind turbine is affected by many factors. Different structural parameters can bring huge differences in turbine performance. Especially the differences in the maximum wind energy utilization (Cp-max) can be more than 30% with different structure. Many new turbines get higher Cp-max by improving the structural parameters. In this paper, the structural improvement information of Savonius wind turbine is summarized in order to provide useful knowledge for the researchers in the structural design and improvement.

You might also be interested in these eBooks

Info:

Periodical:

Advanced Materials Research (Volumes 608-609)

Pages:

467-478

Citation:

Online since:

December 2012

Export:

Price:

[1] Savonius, S.J., The Wing Rotor in Theory and Practice, Savonius Co., Finland, (1928)

Google Scholar

[2] Kedare S. B. , Date A. W. Performance characteristics of a reciprocating wind machine. Journal of Wind Engineering and Industrial Aerodynamics, Vol.22(6) (1999),pp.11-18.

DOI: 10.1016/0167-6105(90)90147-5

Google Scholar

[3] YAO Yingxue,TANG Zhipeng. The development and future of the vertical axis wind turbine. Modern Manufacturing Engineering. Vol.3(2010),pp.136-139. (In Chinese)

Google Scholar

[4] Martino Marini, Aristide Massardo, Antonio Satta. Performance of vertical axis wind turbines with different shapes. Journal of Wind Engineering and Industrial Aerodynamics, 39(1-3) (1992), pp.83-93.

DOI: 10.1016/0167-6105(92)90535-i

Google Scholar

[5] Sandra Eriksson. Evaluation of different turbine concepts for wind power[ J]. Renew Sustain Energy Reviews, 12(5) (2008), pp.1419-1434.

Google Scholar

[6] J L Menet. A double-step Savonius rotors for local production of electricity: A design Study[J] .Renewable Energy, 29 (2004 ), pp.1843-1862

DOI: 10.1016/j.renene.2004.02.011

Google Scholar

[7] J L Menet, Laurent-Charles Valdes, Bruno Menart. A comparative calculation of the wind turbines capacities on the basis of the L-σ criterion. Renewable Energy, 22: (200l), pp.491-506

DOI: 10.1016/s0960-1481(00)00114-2

Google Scholar

[8] I Ushiyama, H Nagai. Optimum design configurations and performances of Savonius rotors.Wind Energy, 12(l) (1998), pp.59-75

Google Scholar

[9] Nobuyuki Fujisawa. Velocity measurements and numerical calculations of flow fields in and around Savonius rotors. Journal of Wind Engineering and Industrial Aerodynamies, 59(1996),pp.39-50.

DOI: 10.1016/0167-6105(94)00031-x

Google Scholar

[10] US Department of Energy, Sandia National Laboratories and American Wind Energy Associotion. Vertical Axis Wind Turbine:The History of the DOE Program [EB/OL]. [SAND96-2205,1996]. http://www.sandia.gov/wind/other/VAWThist. pdf

DOI: 10.2514/6.1980-655

Google Scholar

[11] Sheidahl, R.E. Blackwell, B.F., and Feltz, L.V., Wind Tunnel Performance Data for Two- and Three-Bucket Savonius Rotors, J. ENERGY VOL. 2(3) (1978), p.160~164

DOI: 10.2514/3.47966

Google Scholar

[12] Blade curve influences on the performance of Savonius rotors: experimental and numerical. A Kianifar ,M Anbarsooz .Proc. IMechE Vol. 225 Part A: J. Power and Energy (2011), pp.343-350

DOI: 10.1177/2041296710394413

Google Scholar

[13] Fujisawa N. On the torque mechanism of Savonius rotors. J Wind Eng Ind Aerod. 40 (1992), p.277–92

Google Scholar

[14] Biplab Kumar Debnath, Agnimitra Biswas, and Rajat Gupta. Computational fluid dynamics analysis of a combined three-bucket Savonius and three-bladed Darrieus rotor at various overlap conditions. RENEWABLE AND SUSTAINABLE ENERGY 1, (2009), p.033110(1-13)

DOI: 10.1063/1.3152431

Google Scholar

[15] Li Yan. Resistance-type Vertical Axis Wind Turbine. Renewable Energy Resources. Vol.27 (2) . (2009), pp.119-121. (In Chinese)

Google Scholar

[16] Bach yon G ,Forsch. Gebeite. lngenieurwesens 2 218 (1931)

Google Scholar

[17] Proe. Indian Acad. Sci. (Engg. Sci.), Wind tunnel tests on slow-running vertical-axis wind-rotors. S SIVASEGARAM Vol. 4(3) (1981), p.395-404_9

DOI: 10.1007/bf02843183

Google Scholar

[18] HU Yonghai , TONG Zhengming , WANG Shanshan Bowed Blade Based on Bezier Function and Its Application to VAWT.. Journal of Power Engineering Vol. 29(12) (2009), pp.1155-1159 (In Chinese)

Google Scholar

[19] Vance W. Vertical axis wind rotors – status and potential. In: Proceedings of the conference on wind energy conversion systems. (1973), p.96–102

Google Scholar

[20] Saha UK, Thotla S, Maity D. Optimum design configuration of Savonius rotor through wind tunnel experiments. J Wind Eng Ind Aerod;(96) (2008), p.1359–75.

DOI: 10.1016/j.jweia.2008.03.005

Google Scholar

[21] M.A. Kamoji , S.B. Kedare , S.V. Prabhu .Experimental investigations on single stage modified Savonius rotor. Applied Energy 86 (2009),p.1064–1073

DOI: 10.1016/j.apenergy.2008.09.019

Google Scholar

[22] U.K. Saha, M. Jaya Rajkumar. On the performance analysis of Savonius rotor with twisted blades[J ] . Renewable Energy ,(31) (2006), p.1776 – 1788

DOI: 10.1016/j.renene.2005.08.030

Google Scholar

[23] KAMOJ I M A , KEDARE S B , PRABHU S V. Performance test s on helical Savonius rotors [J. Renewable Energy , (6) (2008), pp.02-04.

Google Scholar

[24] M.A. Kamoji , S.B. Kedare , S.V. Prabhu.Performance tests on helical Savonius rotors. Renewable Energy 34 (2009) , p.521–529.

DOI: 10.1016/j.renene.2008.06.002

Google Scholar

[25] Swapnil V. Ghatage. Jyeshtharaj B. Joshi.Optimisation of Vertical Axis Wind Turbine:CFD Simulations and Experimental Measurements . THE CANADIAN JOURNAL OF CHEMICAL ENGINEERING. Vol.9999,(2011), p.1~16.

DOI: 10.1002/cjce.20617

Google Scholar

[26] Sheldahl RE, Blackwell BF, Feltz LV. Wind tunnel performance data for two and three bucket Savonius rotor. Journal of Energy;(2) (1978), p.160–4.

DOI: 10.2514/3.47966

Google Scholar

[27] Baird JP, Pender SF. Optimization of vertical axis wind turbine for small scale applications. Seventh Autralian hydraulic and fluid mechanics conference, Brisbane, (1980).

Google Scholar

[28] Sivasegaram S, Sivapalan S. Augmentation of power in slow running vertical axis wind rotors using multiple vanes. Journal of Wind Engineering. 7(1) (1983), pp.12-19.

Google Scholar

[29] Huda MD, Selim MA, Islam AKMS, Islam MQ. The performance of an S-shaped Savonius rotor with a deflecting plate. RERIC International Energy Journal;14:(1992), p.25–32.

Google Scholar

[30] Grinspan AS. Development of a low speed wind tunnel and testing of Savonius wind turbine rotor with twisted blades. M. Tech. Thesis. IIT Guwahati, India: Department of Mechanical Engineering; (2002).

Google Scholar

[31] Rajkumar MJ. Experimental investigation and flow simulation of Savonius rotor. M. Tech. Thesis. India: Department of Mechanical Engineering, IIT Guwahati; (2004).

Google Scholar

[32] L-C Valdes , B.Ramamonjisoa. Optimised design and dimensioning of low-technology wind pumps[J] . Renewable Energy. 31(2006)pp.1391-1429.

DOI: 10.1016/j.renene.2005.06.016

Google Scholar

[33] Nobuyuki Fujisawa. Velocity measurement s and numerical calculations of flow fields in and around Savonius rotors[J] . Journal of Wind Engineering and Industrial Aerodynamics. 59 (1996) pp.39-50.

DOI: 10.1016/0167-6105(94)00031-x

Google Scholar

[34] M. A. Kamoji, S. B. Kedare and S. V. Prabhu.Experimental investigations on single stage, two stage and three stage conventional Savonius rotor. International Journal Of Energy Research (2008); 32:p.877–895

DOI: 10.1002/er.1399

Google Scholar

[35] T. Ogawa, H. Yoshida, Y. Yokota. Development of Rotational Speed Control Systems for a SavoniuSavonius Wind Turbine. Journal of Fluids Engineering. 1989, 111(1): pp.53-58

DOI: 10.1115/1.3243598

Google Scholar

[36] SHIKHA T S. Vertical axis wind rotor with concentration by convergent nozzles[J]. Wind Engineering, Vol 27(6) (2003), pp.555-559.

DOI: 10.1260/030952403773617517

Google Scholar

[37] MANABU T. A straight-bladed vertical axis wind turbine with a directed guide vane row-effect of guide vane geometry on the performance. Journal of Thermal Science, 2009, 18(1),pp.54-57.

DOI: 10.1007/s11630-009-0054-0

Google Scholar

[38] WANG Qikun.Numerical Investigation on Aerodynamic Performance for Guiding VAWT with Combined Blades. Journal Of Mechanical Engineering.Vol.47 (2011),p.126~132. (In Chinese)

DOI: 10.3901/jme.2011.12.126

Google Scholar

[39] Burcin Deda Altan,Mehmet Atilgan,Aydogan Ozdamar.An experimental study on improvement of a Savonius rotor performance with curtaining. Experimental Thermal and Fluid Science. Vol 32, (2008),p.1673---1678.

DOI: 10.1016/j.expthermflusci.2008.06.006

Google Scholar

[40] Zhang Luoming,Wang Qiaohong,Zhang Nan,Zhang Xiangwei.Experimental Study on Efficiency of Wind Wheel in Mini – VAWT. China Mechanical Engineering. Vol 20(18), (2009),pp.2186-2189 (In Chinese)

Google Scholar

[41] K. Pope , V. Rodrigues , R. Doylea, A. Tsopelas , R. Gravelsins , G.F. Naterer , E. Tsang.Effects of stator vanes on power coefficients of a zephyr vertical axis wind turbine. Renewable Energy 35 (2010),p.1043–1051

DOI: 10.1016/j.renene.2009.10.012

Google Scholar

[42] Hussain H. Al-Kayiem and Goh Jin Ming. Experimental Investigation of S-Rotors in Open and Bounded Flows. World Academy of Science, Engineering and Technology. 60 (2011),pp.144-149

Google Scholar

[43] Kunio Irabu, Jitendro Nath Roy, Characteristics of wind power on Savonius rotor using a guide-box tunnel. Experimental Thermal and Fluid Science. 2007, 32(2),pp.580-586

DOI: 10.1016/j.expthermflusci.2007.06.008

Google Scholar

[44] Kou Wei, Yuan Bin, Li Qi, Turbine Lintao. Combined Vertical Axis Wind Turbine Design. Electric Power Science and Engineering Vol. 27(5), 2011 p.25~28. (In Chinese)

Google Scholar

[45] Zhao Zhenzhou,Zheng Yuan,Song Chenguang,Zhao Zhenning. Performance of lift- drag combined wind turbine rotor. Journal of Drainage and Irrigation Machinery Engineering . Vol.29 (6) (2011). (In Chinese)

DOI: 10.1109/rsete.2011.5965069

Google Scholar

[46] R. Gupta, A. Biswas, K.K. Sharma. Comparative study of a three-bucket Savonius rotor with a combined three-bucket Savonius–three-bladed Darrieus rotor. Renewable Energy 33 (2008), p.1974–(1981)

DOI: 10.1016/j.renene.2007.12.008

Google Scholar

[47] YANG Huijie, YANG Wentong, The new development of foreign small vertical axis wind generators. Power Demand Side Management . 2007, Vol. 9(2), pp.68-70.(In Chinese)

Google Scholar

[48] Thotla, S.. Optimum design configuration of Savonius rotor through wind tunnel testing. M.Tech. Thesis, Department of Mechanical Engineering, IIT Guwahati, India, (2006)

Google Scholar

[49] Jean-Luc Menet.Prediction of the aerodynamics of a new type of vertical axis wind turbine: the reverse bladed rotor. In: Proc. of the European Wind Energy Conference, (2008).pp.1-9.

Google Scholar

[50] Menet, J.-L. Wind Energy: Aerodynamic behaviour of a new type of slow-running VAWT, Springer-Verlag, chap 43(2006)

DOI: 10.1007/978-3-540-33866-6_43

Google Scholar

[51] Sheldahl R.E., Blackwell B.F., Feltz L.V. Wind Tunnel performance data for two-and three-bucket Savonius rotor. Journal of Energy 2-3 (1978). pp.160-164

DOI: 10.2514/3.47966

Google Scholar

[52] Wilson RE, Lissaman PBS. Applied Aerodynamics of wind power machines. Research Appl. to Nat. Needs, GI-41840, Oregon State University. (1974)

Google Scholar