Development of a novel gauge filled with resin for X-ray CT

Mari Watanabe, Kazuya Matsuzaki4, Osamu Sato5, Souichi Telada, Toshiyuki Takatsuji7
National Institute of Advanced Industrial Science and Technology (AIST)21, Tsukuba, Japan

Abstract: X-ray computed tomography (CT) systems have been widely used for three-dimensional (3D) measurements in the engineering field. Therefore, verifying X-ray CT systems with full traceability is necessary to ensure accurate measurements. Measurement errors of X-ray CT systems are evaluated using a reference gauge whose geometry is calibrated using 3D measuring systems with higher accuracy. Thus, this study developed and characterized a novel reference gauge for X-ray CT systems, comprising spheres embedded in a cylindrical resin.

Keywords: calibration (104), Three-dimensional measurement (3), X-ray CT (28), Verification (2),
*Keywords are freely formed keywords from the authors and thus you may Search also for similar terms.

View:



Watanabe, Mari

Comments or Questions?

Share:
Cite:
Watanabe, M., Matsuzaki, K., Sato, O., Telada, S., & Takatsuji, T. (2022). Development of a novel gauge filled with resin for X-ray CT. 11th Conference on Industrial Computed Tomography (iCT) 2022, 8-11 Feb, Wels, Austria. e-Journal of Nondestructive Testing Vol. 27(3). https://doi.org/10.58286/26637

 Product Spotlight

SRV-J-2-1100 Articulating 2mm Videoscope

The SRV J-2 offers a slim 2mm diameter with articulation. The small bending section allows you to
...
maneuver very tight passages. Clean and crisp images are viewed on the large screen and saved to a removable SD card. Rechargeable battery allows for portability and ease of use.

More from "Kazuya Matsuzaki" (3)
2022-03 Evaluating the geometrical error of dimensional X-ray CT to enhance the measurement accuracy
2018-03 Dimensional X-ray Computed Tomography and its Evaluation Method of Measurement Capability
2016-02 Novel evaluation method of low contrast resolution performance of dimensional X-ray CT
... All 3 Details >
Co-Authored mostly with: T. Takatsuji O. Sato M. Abe H. Fujimoto M. Watanabe

More from "Osamu Sato" (4)
2018-03 Dimensional X-ray Computed Tomography and its Evaluation Method of Measurement Capability
2016-02 Efficient Iterative CT Reconstruction on Octree Guided by Geometric Errors
2016-02 Quality evaluation of X-ray computed tomography volume data in dimensional metrology
2016-02 Novel evaluation method of low contrast resolution performance of dimensional X-ray CT
... All 4 Details >
Co-Authored mostly with: T. Takatsuji M. Abe H. Fujimoto K. Matsuzaki Y. Ohtake


More from "Toshiyuki Takatsuji" (5 of 6)
2019-03 Characterization of resolution performance of novel high energy X-CT : eXTRACT
2018-03 Dimensional X-ray Computed Tomography and its Evaluation Method of Measurement Capability
2016-02 Efficient Iterative CT Reconstruction on Octree Guided by Geometric Errors
2016-02 Quality evaluation of X-ray computed tomography volume data in dimensional metrology
2016-02 Novel evaluation method of low contrast resolution performance of dimensional X-ray CT
... All 6 Details >
Co-Authored mostly with: M. Abe O. Sato H. Fujimoto K. Matsuzaki Y. Ohtake

More from "National Institute of Advanced Industrial Science and Technology (AIST)" (5 of 20)
2024-04 Development of a Single-Sided Magnetic Resonance Surface Scanner: Towards Non-Destructive Quantification of Moisture in Slaked Lime Plaster for Maintenance and Remediation of Heritage Architecture
2022-03 Evaluating the geometrical error of dimensional X-ray CT to enhance the measurement accuracy
2021-07 Benchmarking Deep Learning Models for Automatic Ultrasonic Imaging Inspection
2019-04 Carbon-based Printed Strain Sensor Array and Wireless Measuring System for Application to Structural Health Monitoring
2019-03 Characterization of resolution performance of novel high energy X-CT : eXTRACT
... All 20 Details >
Co-Authored mostly with: Shutoko Engineering ... Aoyama Gakuin Univer... Tokyo Institute of T... Tohoku University... NMEMS Technology Res...

More Videos at NDT.net

 Product Spotlight

Conformable wedge transducer

The conformability is obtained with a flexible membrane filled with water between the transducer and
...
the inspected component. The coupling between the membrane and the component requires a small quantity of water or couplant. The conformable wedge combines the acoustic performance of immersion technique with good coupling and low attenuation.

OEM-PA Max

Top of the line performance FMC, PWI, Phased Array Ultra-High speed (1GB/s) AWG (Arbitrary Wav
...
eform Generator) option Can be daisy-chained for multi-electronic or multi-probe applications 64/64, 64/128, 64/256 Small form factor OEM-PA Max is the new leading edge of what can be found in the FMC/TFM family of beamformers. It’s outstanding speed of 1GB/s (using 10Gb Ethernet) for a batch of 64ch allows any acquisition to be as quick in FMC as in Phased Array. The AWG (Arbitrary Waveform Generator) option, which allows the emission of tone bursts, Chirps Gaussian waveforms as well as any user defined waveform, permits to use encoded pulser shapes to improve super-resolution and SNR. Since OEM-PA Max also manages all Phased Array processing, it provides all the versatility you can expect or need, and in a very small form factor that makes any application possible.

OEM Ultrasonic opBox ver 2.3! OEM Ultrasonic device with integrated 2-channel pulser&receiver.

The opBox family are high-performance, precise, UT devices, designed for use in ultrasonic NDT sys
...
tems, but also suitable for other measurements. Due to their flexibility and easy to use sw, opBoxes are ideal for testing: weld inspection for cracks and volume defects soldered and coated joints, wall, shafts, rods, tubes and sheets plastics or fibre or any ultrasonic material characterization.

PAUT Probes

Typical Phased Array probes have frequencies between 1MHz and 20MHz and the number of wafers is 10
...
to 128. M2 Electronics offers customers conventionally ultrasound probes and the ability to provide high-precision Phased Array Ultrasound Probes of up to 256 wafers. We can also customize the probe for our customers to meet the specific application requirements of the user.